--Version: v5.0.0 --Date: 05/12/2010 --Copyright @ 2010 RLE Technologies. All rights reserved worldwide. --This MIB defines objects for the RLE FDSWI SNMP Agent. RLE-FDSWI-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString FROM RFC1213-MIB OBJECT-TYPE, enterprises FROM RFC1155-SMI TRAP-TYPE FROM RFC-1215; rle OBJECT IDENTIFIER ::= { enterprises 3184 } products OBJECT IDENTIFIER ::= { rle 1 } fds OBJECT IDENTIFIER ::= { products 10 } fdsWi OBJECT IDENTIFIER ::= { fds 1 } fdsIdent OBJECT IDENTIFIER ::= { fdsWi 1 } fdsIdentManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit manufacturer." ::= { fdsIdent 1 } fdsIdentModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit Model designation." ::= { fdsIdent 2 } fdsIdentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The SNMP Agent software version." ::= { fdsIdent 3 } fdsSensors OBJECT IDENTIFIER ::= { fdsWi 2 } numberOfSensors OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The number of sensors recorded by the FDS. Used to indicate the number of sensorTable entries." ::= { fdsSensors 1 } sensorTable OBJECT-TYPE SYNTAX SEQUENCE OF InputTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of snmp input object values." ::= { fdsSensors 2 } sensorTableEntry OBJECT-TYPE SYNTAX InputTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An input table entry containing data for a specific sensor." INDEX { sensorIndex } ::= { sensorTable 1 } InputTableEntry ::= SEQUENCE { sensorIndex INTEGER, sensorModel DisplayString, sensorID DisplayString, sensorOutOfService INTEGER, sensorSerialNumber DisplayString, sensorRawData1 DisplayString, sensorRawData2 DisplayString, sensorRawData3 DisplayString, sensorConvertedData1 INTEGER, sensorConvertedData2 INTEGER, sensorConvertedData3 INTEGER, sensorAge INTEGER, sensorOfflineDelay INTEGER, sensorLabel DisplayString } sensorIndex OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The index in the input table for a particular snmp sensor object. Used to address table entries." ::= { sensorTableEntry 1 } sensorModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Model string" ::= { sensorTableEntry 2 } sensorID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor ID string - two byte ascii string" ::= { sensorTableEntry 3 } sensorOutOfService OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor out of service mode indicator" ::= { sensorTableEntry 4 } sensorSerialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor Serial Number - sixteen byte ascii string" ::= { sensorTableEntry 5 } sensorRawData1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #1 in raw hex" ::= { sensorTableEntry 6 } sensorRawData2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #2 in raw hex" ::= { sensorTableEntry 7 } sensorRawData3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #3 in raw hex" ::= { sensorTableEntry 8 } sensorConvertedData1 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #1 in a converted value based on the sensor model" ::= { sensorTableEntry 9 } sensorConvertedData2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #2 in a converted value based on the sensor model" ::= { sensorTableEntry 10 } sensorConvertedData3 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor data field #3 in a converted value based on the sensor model" ::= { sensorTableEntry 11 } sensorAge OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The age of the sensor data in seconds" ::= { sensorTableEntry 12 } sensorOfflineDelay OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The delay time in minutes that a sensor is flagged as out of service" ::= { sensorTableEntry 13 } sensorLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The sensor description label" ::= { sensorTableEntry 14 } fdsWiTrapData OBJECT IDENTIFIER ::= { fdsWi 3 } fdsWiTrapSensorNumber OBJECT-TYPE SYNTAX INTEGER ACCESS not-accessible STATUS mandatory DESCRIPTION "The sensor number (1-400)." ::= { fdsWiTrapData 1 } fdsWiTrapSensorLabel OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "The sensor description label." ::= { fdsWiTrapData 2 } fdsWiTrapSensorText OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "A text string associated with the sensor trap." ::= { fdsWiTrapData 3 } fdsWiTraps OBJECT IDENTIFIER ::= { fdsWi 4 } fdsWiSensorAlarmTrap TRAP-TYPE ENTERPRISE fdsWiTraps VARIABLES { fdsWiTrapSensorNumber, fdsWiTrapSensorLabel, fdsWiTrapSensorText } DESCRIPTION "A sensor has reached an alarm state." ::= 1 fdsWiSensorWarningTrap TRAP-TYPE ENTERPRISE fdsWiTraps VARIABLES { fdsWiTrapSensorNumber, fdsWiTrapSensorLabel, fdsWiTrapSensorText } DESCRIPTION "A sensor has reached a warning state." ::= 2 fdsWiSensorOfflineTrap TRAP-TYPE ENTERPRISE fdsWiTraps VARIABLES { fdsWiTrapSensorNumber, fdsWiTrapSensorLabel, fdsWiTrapSensorText } DESCRIPTION "A sensor has went offline." ::= 3 fdsWiSensorReturnToNormalTrap TRAP-TYPE ENTERPRISE fdsWiTraps VARIABLES { fdsWiTrapSensorNumber, fdsWiTrapSensorLabel, fdsWiTrapSensorText } DESCRIPTION "A sensor alarm/warning has returned to normal." ::= 4 END