-- Title: FALCON8a.MIB -- Version: v6.5 -- Date: 04/23/02 11:30am -- -- Copyright @ 2002 RLE Technologies. All rights reserved worldwide. -- -- This MIB defines objects for the RLE falcon SNMP Agent. -- RLE-FALCON-MIB DEFINITIONS ::= BEGIN IMPORTS TruthValue FROM RFC1253 DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212 Counter, enterprises FROM RFC1155-SMI; PositiveInteger ::= INTEGER (1..'FFFFFFFF'h) rle OBJECT IDENTIFIER ::= { enterprises 3184 } products OBJECT IDENTIFIER ::= { rle 1 } falcon OBJECT IDENTIFIER ::= { products 1 } falconMIB OBJECT IDENTIFIER ::= { falcon 1 } falconIdent OBJECT IDENTIFIER ::= { falconMIB 1 } falconIdentManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit manufacturer." ::= { falconIdent 1 } falconIdentModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit Model designation." ::= { falconIdent 2 } falconIdentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The falcon SNMP Agent software version." ::= { falconIdent 3 } falconIdentSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to MIB definitions specific to the particular Monitor Unit being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value." ::= { falconIdent 4 } falconSystem OBJECT IDENTIFIER ::= { falconMIB 2 } falconClock OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon internal clock settings. Displayed as MM/DD/YY HH:MM:SS" ::= { falconSystem 1 } falconDoorAlarmBypass OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The falcon door alarm bypass switch. This allows the alarm to be bypassed upon valid keypad access. Zero disables this, or use 1 thru 8 for the corresponding falcon input." ::= { falconSystem 2 } falconKeypad OBJECT IDENTIFIER ::= { falconSystem 3 } falconKeypadCode1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #1. This can be up to six numberic characters." ::= { falconKeypad 1 } falconKeypadName1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #1. This can be up to 20 characters." ::= { falconKeypad 2 } falconKeypadCode2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #2. This can be up to six numberic characters." ::= { falconKeypad 3 } falconKeypadName2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #2. This can be up to 20 characters." ::= { falconKeypad 4 } falconKeypadCode3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #3. This can be up to six numberic characters." ::= { falconKeypad 5 } falconKeypadName3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #3. This can be up to 20 characters." ::= { falconKeypad 6 } falconKeypadCode4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #4. This can be up to six numberic characters." ::= { falconKeypad 7 } falconKeypadName4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #4. This can be up to 20 characters." ::= { falconKeypad 8 } falconKeypadCode5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #5. This can be up to six numberic characters." ::= { falconKeypad 9 } falconKeypadName5 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #5. This can be up to 20 characters." ::= { falconKeypad 10 } falconKeypadCode6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #6. This can be up to six numberic characters." ::= { falconKeypad 11 } falconKeypadName6 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #6. This can be up to 20 characters." ::= { falconKeypad 12 } falconKeypadCode7 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #7. This can be up to six numberic characters." ::= { falconKeypad 13 } falconKeypadName7 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #7. This can be up to 20 characters." ::= { falconKeypad 14 } falconKeypadCode8 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #8. This can be up to six numberic characters." ::= { falconKeypad 15 } falconKeypadName8 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #8. This can be up to 20 characters." ::= { falconKeypad 16 } falconKeypadCode9 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #9. This can be up to six numberic characters." ::= { falconKeypad 17 } falconKeypadName9 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #9. This can be up to 20 characters." ::= { falconKeypad 18 } falconKeypadCode10 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #10. This can be up to six numberic characters." ::= { falconKeypad 19 } falconKeypadName10 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #10. This can be up to 20 characters." ::= { falconKeypad 20 } falconKeypadCode11 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #11. This can be up to six numberic characters." ::= { falconKeypad 21 } falconKeypadName11 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #11. This can be up to 20 characters." ::= { falconKeypad 22 } falconKeypadCode12 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #12. This can be up to six numberic characters." ::= { falconKeypad 23 } falconKeypadName12 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #12. This can be up to 20 characters." ::= { falconKeypad 24 } falconKeypadCode13 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #13. This can be up to six numberic characters." ::= { falconKeypad 25 } falconKeypadName13 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #13. This can be up to 20 characters." ::= { falconKeypad 26 } falconKeypadCode14 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #14. This can be up to six numberic characters." ::= { falconKeypad 27 } falconKeypadName14 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #14. This can be up to 20 characters." ::= { falconKeypad 28 } falconKeypadCode15 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #15. This can be up to six numberic characters." ::= { falconKeypad 29 } falconKeypadName15 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #15. This can be up to 20 characters." ::= { falconKeypad 30 } falconKeypadCode16 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #16. This can be up to six numberic characters." ::= { falconKeypad 31 } falconKeypadName16 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #16. This can be up to 20 characters." ::= { falconKeypad 32 } falconKeypadCode17 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #17. This can be up to six numberic characters." ::= { falconKeypad 33 } falconKeypadName17 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #17. This can be up to 20 characters." ::= { falconKeypad 34 } falconKeypadCode18 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #18. This can be up to six numberic characters." ::= { falconKeypad 35 } falconKeypadName18 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #18. This can be up to 20 characters." ::= { falconKeypad 36 } falconKeypadCode19 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #19. This can be up to six numberic characters." ::= { falconKeypad 37 } falconKeypadName19 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #19. This can be up to 20 characters." ::= { falconKeypad 38 } falconKeypadCode20 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #20. This can be up to six numberic characters." ::= { falconKeypad 39 } falconKeypadName20 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #20. This can be up to 20 characters." ::= { falconKeypad 40 } falconInputVoltage OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The falcon input voltage (DC Power)." ::= { falconSystem 4 } falconOnBattery OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), installed(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of the On Battery Alarm. When the State is set to installed(1), the On Battery and Low Battery alarms are enabled. This variable is stored in non-volatile memory." ::= { falconSystem 5 } falconLowBatteryThreshold OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The low voltage trip point for the low battery alarm. When the input voltage goes below this voltage, the Low Battery alarm is set. This variable is stored in non-volatile memory." ::= { falconSystem 6 } falconAnalogAverage OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "This is the analog averaging duration in seconds. The analog input readings are averaged for this time period before updating. This value must be set to 1,2,3,4,5,6,10,15,20,30 or 60 seconds. This variable is stored in non-volatile memory." ::= { falconSystem 7 } falconPagerStatusString OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The falcon last page status char string." ::= { falconSystem 8 } falconInputs OBJECT IDENTIFIER ::= { falconMIB 3 } falconInput1 OBJECT IDENTIFIER ::= { falconInputs 1 } falconInput1State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 1. When a sensor is connected to Input 1 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 1 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput1 1 } falconInput1Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 1. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput1 2 } falconInput1Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 1 to obtain the value of the Input1 variable. The gain variable is stored in non-volatile memory." ::= { falconInput1 3 } falconInput1Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 1 to obtain the value of the Input1 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput1 4 } falconInput1Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 1. The text string is stored in non-volatile memory." ::= { falconInput1 5 } falconInput1UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 1. The text string is stored in non-volatile memory." ::= { falconInput1 6 } falconInput1HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 1 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 1. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput1 7 } falconInput1HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 1 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 1. The HighLimit variable is stored in non-volatile memory." ::= { falconInput1 8 } falconInput1LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 1 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 1. The LowLimit variable is stored in non-volatile memory." ::= { falconInput1 9 } falconInput1LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 1 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 1. The LowLimit variable is stored in non-volatile memory." ::= { falconInput1 10 } falconInput1RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput1 11 } falconInput1Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput1 12 } falconInput1Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput1 13 } falconInput1Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 1." ::= { falconInput1 14 } falconInput1DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 1. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput1 15 } falconInput2 OBJECT IDENTIFIER ::= { falconInputs 2 } falconInput2State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 2. When a sensor is connected to Input 2 set State to installed(2) to indicate that the value of falconReading2 is valid. When no sensor is connected to Input 2 set State to notInstalled(1) to indicate that the value of falconReading2 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput2 1 } falconInput2Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput2 2 } falconInput2Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 2 to obtain the value of the Input2 variable. The gain variable is stored in non-volatile memory." ::= { falconInput2 3 } falconInput2Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 2 to obtain the value of the Input2 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput2 4 } falconInput2Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory." ::= { falconInput2 5 } falconInput2UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory." ::= { falconInput2 6 } falconInput2HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 2 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 2. The HighLimit variable is stored in non-volatile memory." ::= { falconInput2 7 } falconInput2HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 2 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 2. The HighLimit variable is stored in non-volatile memory." ::= { falconInput2 8 } falconInput2LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 2 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 2. The LowLimit variable is stored in non-volatile memory." ::= { falconInput2 9 } falconInput2LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 2 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 2. The LowLimit variable is stored in non-volatile memory." ::= { falconInput2 10 } falconInput2RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput2 11 } falconInput2Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput2 12 } falconInput2Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput2 13 } falconInput2Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 2." ::= { falconInput2 14 } falconInput2DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 2. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput2 15 } falconInput3 OBJECT IDENTIFIER ::= { falconInputs 3 } falconInput3State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 3. When a sensor is connected to Input 3 set State to installed(2) to indicate that the value of falconReading3 is valid. When no sensor is connected to Input 3 set State to notInstalled(1) to indicate that the value of falconReading3 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput3 1 } falconInput3Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput3 2 } falconInput3Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 3 to obtain the value of the Input3 variable. The gain variable is stored in non-volatile memory." ::= { falconInput3 3 } falconInput3Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 3 to obtain the value of the Input3 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput3 4 } falconInput3Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 3. The text string is stored in non-volatile memory." ::= { falconInput3 5 } falconInput3UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 3. The text string is stored in non-volatile memory." ::= { falconInput3 6 } falconInput3HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 3. The HighLimit variable is stored in non-volatile memory." ::= { falconInput3 7 } falconInput3HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 3. The HighLimit variable is stored in non-volatile memory." ::= { falconInput3 8 } falconInput3LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 3. The LowLimit variable is stored in non-volatile memory." ::= { falconInput3 9 } falconInput3LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 3 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 3. The LowLimit variable is stored in non-volatile memory." ::= { falconInput3 10 } falconInput3RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput3 11 } falconInput3Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput3 12 } falconInput3Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput3 13 } falconInput3Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 3." ::= { falconInput3 14 } falconInput3DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 3. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput3 15 } falconInput4 OBJECT IDENTIFIER ::= { falconInputs 4 } falconInput4State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 4. When a sensor is connected to Input 4 set State to installed(2) to indicate that the value of falconReading4 is valid. When no sensor is connected to Input 4 set State to notInstalled(1) to indicate that the value of falconReading4 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput4 1 } falconInput4Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput4 2 } falconInput4Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 4 to obtain the value of the Input4 variable. The gain variable is stored in non-volatile memory." ::= { falconInput4 3 } falconInput4Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 4 to obtain the value of the Input4 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput4 4 } falconInput4Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 4. The text string is stored in non-volatile memory." ::= { falconInput4 5 } falconInput4UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 4. The text string is stored in non-volatile memory." ::= { falconInput4 6 } falconInput4HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 4 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 4. The HighLimit variable is stored in non-volatile memory." ::= { falconInput4 7 } falconInput4HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 4 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 4. The HighLimit variable is stored in non-volatile memory." ::= { falconInput4 8 } falconInput4LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 4 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 4. The LowLimit variable is stored in non-volatile memory." ::= { falconInput4 9 } falconInput4LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 4 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 4. The LowLimit variable is stored in non-volatile memory." ::= { falconInput4 10 } falconInput4RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput4 11 } falconInput4Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput4 12 } falconInput4Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput4 13 } falconInput4Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 4." ::= { falconInput4 14 } falconInput4DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 4. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput4 15 } falconInput5 OBJECT IDENTIFIER ::= { falconInputs 5 } falconInput5State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 5. When a sensor is connected to Input 5 set State to installed(2) to indicate that the value of falconReading4 is valid. When no sensor is connected to Input 5 set State to notInstalled(1) to indicate that the value of falconReading5 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput5 1 } falconInput5Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 5. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput5 2 } falconInput5Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 5 to obtain the value of the Input5 variable. The gain variable is stored in non-volatile memory." ::= { falconInput5 3 } falconInput5Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 5 to obtain the value of the Input5 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput5 4 } falconInput5Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 5. The text string is stored in non-volatile memory." ::= { falconInput5 5 } falconInput5UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 5. The text string is stored in non-volatile memory." ::= { falconInput5 6 } falconInput5HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 5 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 5. The HighLimit variable is stored in non-volatile memory." ::= { falconInput5 7 } falconInput5HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 5 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 5. The HighLimit variable is stored in non-volatile memory." ::= { falconInput5 8 } falconInput5LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 5 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 5. The LowLimit variable is stored in non-volatile memory." ::= { falconInput5 9 } falconInput5LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 5 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 5. The LowLimit variable is stored in non-volatile memory." ::= { falconInput5 10 } falconInput5RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput5 11 } falconInput5Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput5 12 } falconInput5Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput5 13 } falconInput5Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 5." ::= { falconInput5 14 } falconInput5DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 5. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput5 15 } falconInput6 OBJECT IDENTIFIER ::= { falconInputs 6 } falconInput6State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 6. When a sensor is connected to Input 6 set State to installed(2) to indicate that the value of falconReading6 is valid. When no sensor is connected to Input 6 set State to notInstalled(1) to indicate that the value of falconReading6 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput6 1 } falconInput6Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 6. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput6 2 } falconInput6Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 6 to obtain the value of the Input6 variable. The gain variable is stored in non-volatile memory." ::= { falconInput6 3 } falconInput6Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 6 to obtain the value of the Input6 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput6 4 } falconInput6Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 6. The text string is stored in non-volatile memory." ::= { falconInput6 5 } falconInput6UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 6. The text string is stored in non-volatile memory." ::= { falconInput6 6 } falconInput6HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 6 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 6. The HighLimit variable is stored in non-volatile memory." ::= { falconInput6 7 } falconInput6HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 6 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 6. The HighLimit variable is stored in non-volatile memory." ::= { falconInput6 8 } falconInput6LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 6 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 6. The LowLimit variable is stored in non-volatile memory." ::= { falconInput6 9 } falconInput6LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 6 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 6. The LowLimit variable is stored in non-volatile memory." ::= { falconInput6 10 } falconInput6RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput6 11 } falconInput6Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput6 12 } falconInput6Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput6 13 } falconInput6Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 6." ::= { falconInput6 14 } falconInput6DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 6. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput6 15 } falconInput7 OBJECT IDENTIFIER ::= { falconInputs 7 } falconInput7State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 7. When a sensor is connected to Input 7 set State to installed(2) to indicate that the value of falconReading4 is valid. When no sensor is connected to Input 7 set State to notInstalled(1) to indicate that the value of falconReading7 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput7 1 } falconInput7Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 7. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput7 2 } falconInput7Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 7 to obtain the value of the Input7 variable. The gain variable is stored in non-volatile memory." ::= { falconInput7 3 } falconInput7Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 7 to obtain the value of the Input7 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput7 4 } falconInput7Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 7. The text string is stored in non-volatile memory." ::= { falconInput7 5 } falconInput7UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 7. The text string is stored in non-volatile memory." ::= { falconInput7 6 } falconInput7HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 7 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 7. The HighLimit variable is stored in non-volatile memory." ::= { falconInput7 7 } falconInput7HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 7 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 7. The HighLimit variable is stored in non-volatile memory." ::= { falconInput7 8 } falconInput7LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 7 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 7. The LowLimit variable is stored in non-volatile memory." ::= { falconInput7 9 } falconInput7LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 7 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 7. The LowLimit variable is stored in non-volatile memory." ::= { falconInput7 10 } falconInput7RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput7 11 } falconInput7Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput7 12 } falconInput7Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput7 13 } falconInput7Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 7." ::= { falconInput7 14 } falconInput7DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 7. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput7 15 } falconInput8 OBJECT IDENTIFIER ::= { falconInputs 8 } falconInput8State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 8. When a sensor is connected to Input 8 set State to installed(2) to indicate that the value of falconReading8 is valid. When no sensor is connected to Input 8 set State to notInstalled(1) to indicate that the value of falconReading8 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput8 1 } falconInput8Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 8. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput8 2 } falconInput8Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 8 to obtain the value of the Input8 variable. The gain variable is stored in non-volatile memory." ::= { falconInput8 3 } falconInput8Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 8 to obtain the value of the Input8 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput8 4 } falconInput8Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory." ::= { falconInput8 5 } falconInput8UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory." ::= { falconInput8 6 } falconInput8HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 8 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 8. The HighLimit variable is stored in non-volatile memory." ::= { falconInput8 7 } falconInput8HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 8 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 8. The HighLimit variable is stored in non-volatile memory." ::= { falconInput8 8 } falconInput8LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 8 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 8. The LowLimit variable is stored in non-volatile memory." ::= { falconInput8 9 } falconInput8LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 8 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 8. The LowLimit variable is stored in non-volatile memory." ::= { falconInput8 10 } falconInput8RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput8 11 } falconInput8Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput8 12 } falconInput8Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput8 13 } falconInput8Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 8." ::= { falconInput8 14 } falconInput8DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 8. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput8 15 } falconInput9 OBJECT IDENTIFIER ::= { falconInputs 9 } falconInput9State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 9. When a sensor is connected to Input 9 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 9 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput9 1 } falconInput9Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 9. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput9 2 } falconInput9Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 9 to obtain the value of the Input9 variable. The gain variable is stored in non-volatile memory." ::= { falconInput9 3 } falconInput9Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 9 to obtain the value of the Input9 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput9 4 } falconInput9Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 9. The text string is stored in non-volatile memory." ::= { falconInput9 5 } falconInput9UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 9. The text string is stored in non-volatile memory." ::= { falconInput9 6 } falconInput9HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 9 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 9. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput9 7 } falconInput9HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 9 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 9. The HighLimit variable is stored in non-volatile memory." ::= { falconInput9 8 } falconInput9LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 9 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 9. The LowLimit variable is stored in non-volatile memory." ::= { falconInput9 9 } falconInput9LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 9 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 9. The LowLimit variable is stored in non-volatile memory." ::= { falconInput9 10 } falconInput9RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput9 11 } falconInput9Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput9 12 } falconInput9Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput9 13 } falconInput9Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 9." ::= { falconInput9 14 } falconInput9DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 9. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput9 15 } falconInput10 OBJECT IDENTIFIER ::= { falconInputs 10 } falconInput10State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 10. When a sensor is connected to Input 10 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 10 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput10 1 } falconInput10Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 10. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput10 2 } falconInput10Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 10 to obtain the value of the Input10 variable. The gain variable is stored in non-volatile memory." ::= { falconInput10 3 } falconInput10Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 10 to obtain the value of the Input10 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput10 4 } falconInput10Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 10. The text string is stored in non-volatile memory." ::= { falconInput10 5 } falconInput10UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 10. The text string is stored in non-volatile memory." ::= { falconInput10 6 } falconInput10HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 10 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 10. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput10 7 } falconInput10HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 10 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 10. The HighLimit variable is stored in non-volatile memory." ::= { falconInput10 8 } falconInput10LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 10 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 10. The LowLimit variable is stored in non-volatile memory." ::= { falconInput10 9 } falconInput10LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 10 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 10. The LowLimit variable is stored in non-volatile memory." ::= { falconInput10 10 } falconInput10RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput10 11 } falconInput10Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput10 12 } falconInput10Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput10 13 } falconInput10Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 10." ::= { falconInput10 14 } falconInput10DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 10. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput10 15 } falconInput11 OBJECT IDENTIFIER ::= { falconInputs 11 } falconInput11State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 11. When a sensor is connected to Input 11 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 11 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput11 1 } falconInput11Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 11. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput11 2 } falconInput11Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 11 to obtain the value of the Input11 variable. The gain variable is stored in non-volatile memory." ::= { falconInput11 3 } falconInput11Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 11 to obtain the value of the Input11 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput11 4 } falconInput11Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 11. The text string is stored in non-volatile memory." ::= { falconInput11 5 } falconInput11UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 11. The text string is stored in non-volatile memory." ::= { falconInput11 6 } falconInput11HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 11 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 11. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput11 7 } falconInput11HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 11 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 11. The HighLimit variable is stored in non-volatile memory." ::= { falconInput11 8 } falconInput11LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 11 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 11. The LowLimit variable is stored in non-volatile memory." ::= { falconInput11 9 } falconInput11LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 11 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 11. The LowLimit variable is stored in non-volatile memory." ::= { falconInput11 10 } falconInput11RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput11 11 } falconInput11Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput11 12 } falconInput11Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput11 13 } falconInput11Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 11." ::= { falconInput11 14 } falconInput11DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 11. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput11 15 } falconInput12 OBJECT IDENTIFIER ::= { falconInputs 12 } falconInput12State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 12. When a sensor is connected to Input 12 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 12 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput12 1 } falconInput12Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 12. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput12 2 } falconInput12Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 12 to obtain the value of the Input12 variable. The gain variable is stored in non-volatile memory." ::= { falconInput12 3 } falconInput12Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 12 to obtain the value of the Input12 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput12 4 } falconInput12Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 12. The text string is stored in non-volatile memory." ::= { falconInput12 5 } falconInput12UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 12. The text string is stored in non-volatile memory." ::= { falconInput12 6 } falconInput12HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 12 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 12. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput12 7 } falconInput12HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 12 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 12. The HighLimit variable is stored in non-volatile memory." ::= { falconInput12 8 } falconInput12LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 12 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 12. The LowLimit variable is stored in non-volatile memory." ::= { falconInput12 9 } falconInput12LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 12 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 12. The LowLimit variable is stored in non-volatile memory." ::= { falconInput12 10 } falconInput12RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput12 11 } falconInput12Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput12 12 } falconInput12Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput12 13 } falconInput12Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 12." ::= { falconInput12 14 } falconInput12DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 12. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput12 15 } falconInput13 OBJECT IDENTIFIER ::= { falconInputs 13 } falconInput13State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 13. When a sensor is connected to Input 13 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 13 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput13 1 } falconInput13Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 13. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput13 2 } falconInput13Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 13 to obtain the value of the Input13 variable. The gain variable is stored in non-volatile memory." ::= { falconInput13 3 } falconInput13Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 13 to obtain the value of the Input13 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput13 4 } falconInput13Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 13. The text string is stored in non-volatile memory." ::= { falconInput13 5 } falconInput13UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 13. The text string is stored in non-volatile memory." ::= { falconInput13 6 } falconInput13HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 13 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 13. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput13 7 } falconInput13HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 13 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 13. The HighLimit variable is stored in non-volatile memory." ::= { falconInput13 8 } falconInput13LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 13 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 13. The LowLimit variable is stored in non-volatile memory." ::= { falconInput13 9 } falconInput13LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 13 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 13. The LowLimit variable is stored in non-volatile memory." ::= { falconInput13 10 } falconInput13RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput13 11 } falconInput13Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput13 12 } falconInput13Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput13 13 } falconInput13Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 13." ::= { falconInput13 14 } falconInput13DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 13. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput13 15 } falconInput14 OBJECT IDENTIFIER ::= { falconInputs 14 } falconInput14State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 14. When a sensor is connected to Input 14 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 14 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput14 1 } falconInput14Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 14. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput14 2 } falconInput14Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 14 to obtain the value of the Input14 variable. The gain variable is stored in non-volatile memory." ::= { falconInput14 3 } falconInput14Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 14 to obtain the value of the Input14 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput14 4 } falconInput14Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 14. The text string is stored in non-volatile memory." ::= { falconInput14 5 } falconInput14UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 14. The text string is stored in non-volatile memory." ::= { falconInput14 6 } falconInput14HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 14 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 14. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput14 7 } falconInput14HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 14 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 14. The HighLimit variable is stored in non-volatile memory." ::= { falconInput14 8 } falconInput14LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 14 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 14. The LowLimit variable is stored in non-volatile memory." ::= { falconInput14 9 } falconInput14LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 14 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 14. The LowLimit variable is stored in non-volatile memory." ::= { falconInput14 10 } falconInput14RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput14 11 } falconInput14Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput14 12 } falconInput14Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput14 13 } falconInput14Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 14." ::= { falconInput14 14 } falconInput14DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 14. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput14 15 } falconInput15 OBJECT IDENTIFIER ::= { falconInputs 15 } falconInput15State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 15. When a sensor is connected to Input 15 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 15 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput15 1 } falconInput15Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 15. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput15 2 } falconInput15Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 15 to obtain the value of the Input15 variable. The gain variable is stored in non-volatile memory." ::= { falconInput15 3 } falconInput15Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 15 to obtain the value of the Input15 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput15 4 } falconInput15Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 15. The text string is stored in non-volatile memory." ::= { falconInput15 5 } falconInput15UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 15. The text string is stored in non-volatile memory." ::= { falconInput15 6 } falconInput15HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 15 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 15. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput15 7 } falconInput15HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 15 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 15. The HighLimit variable is stored in non-volatile memory." ::= { falconInput15 8 } falconInput15LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 15 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 15. The LowLimit variable is stored in non-volatile memory." ::= { falconInput15 9 } falconInput15LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 15 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 15. The LowLimit variable is stored in non-volatile memory." ::= { falconInput15 10 } falconInput15RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput15 11 } falconInput15Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput15 12 } falconInput15Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput15 13 } falconInput15Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 15." ::= { falconInput15 14 } falconInput15DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 15. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput15 15 } falconInput16 OBJECT IDENTIFIER ::= { falconInputs 16 } falconInput16State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 16. When a sensor is connected to Input 16 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 16 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput16 1 } falconInput16Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 16. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput16 2 } falconInput16Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 16 to obtain the value of the Input16 variable. The gain variable is stored in non-volatile memory." ::= { falconInput16 3 } falconInput16Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 16 to obtain the value of the Input16 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput16 4 } falconInput16Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 16. The text string is stored in non-volatile memory." ::= { falconInput16 5 } falconInput16UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 16. The text string is stored in non-volatile memory." ::= { falconInput16 6 } falconInput16HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 16 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 16. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput16 7 } falconInput16HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 16 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 16. The HighLimit variable is stored in non-volatile memory." ::= { falconInput16 8 } falconInput16LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 16 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 16. The LowLimit variable is stored in non-volatile memory." ::= { falconInput16 9 } falconInput16LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 16 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 16. The LowLimit variable is stored in non-volatile memory." ::= { falconInput16 10 } falconInput16RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput16 11 } falconInput16Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput16 12 } falconInput16Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput16 13 } falconInput16Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 16." ::= { falconInput16 14 } falconInput16DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 16. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput16 15 } falconInput17 OBJECT IDENTIFIER ::= { falconInputs 17 } falconInput17State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 17. When a sensor is connected to Input 17 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 17 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput17 1 } falconInput17Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 17. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput17 2 } falconInput17Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 17 to obtain the value of the Input17 variable. The gain variable is stored in non-volatile memory." ::= { falconInput17 3 } falconInput17Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 17 to obtain the value of the Input17 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput17 4 } falconInput17Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 17. The text string is stored in non-volatile memory." ::= { falconInput17 5 } falconInput17UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 17. The text string is stored in non-volatile memory." ::= { falconInput17 6 } falconInput17HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 17 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 17. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput17 7 } falconInput17HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 17 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 17. The HighLimit variable is stored in non-volatile memory." ::= { falconInput17 8 } falconInput17LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 17 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 17. The LowLimit variable is stored in non-volatile memory." ::= { falconInput17 9 } falconInput17LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 17 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 17. The LowLimit variable is stored in non-volatile memory." ::= { falconInput17 10 } falconInput17RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput17 11 } falconInput17Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput17 12 } falconInput17Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput17 13 } falconInput17Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 17." ::= { falconInput17 14 } falconInput17DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 17. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput17 15 } falconInput18 OBJECT IDENTIFIER ::= { falconInputs 18 } falconInput18State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 18. When a sensor is connected to Input 18 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 18 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput18 1 } falconInput18Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 18. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput18 2 } falconInput18Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 18 to obtain the value of the Input18 variable. The gain variable is stored in non-volatile memory." ::= { falconInput18 3 } falconInput18Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 18 to obtain the value of the Input18 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput18 4 } falconInput18Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 18. The text string is stored in non-volatile memory." ::= { falconInput18 5 } falconInput18UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 18. The text string is stored in non-volatile memory." ::= { falconInput18 6 } falconInput18HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 18 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 18. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput18 7 } falconInput18HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 18 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 18. The HighLimit variable is stored in non-volatile memory." ::= { falconInput18 8 } falconInput18LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 18 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 18. The LowLimit variable is stored in non-volatile memory." ::= { falconInput18 9 } falconInput18LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 18 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 18. The LowLimit variable is stored in non-volatile memory." ::= { falconInput18 10 } falconInput18RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput18 11 } falconInput18Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput18 12 } falconInput18Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput18 13 } falconInput18Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 18." ::= { falconInput18 14 } falconInput18DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 18. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput18 15 } falconInput19 OBJECT IDENTIFIER ::= { falconInputs 19 } falconInput19State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 19. When a sensor is connected to Input 19 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 19 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput19 1 } falconInput19Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 19. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput19 2 } falconInput19Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 19 to obtain the value of the Input19 variable. The gain variable is stored in non-volatile memory." ::= { falconInput19 3 } falconInput19Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 19 to obtain the value of the Input19 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput19 4 } falconInput19Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 19. The text string is stored in non-volatile memory." ::= { falconInput19 5 } falconInput19UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 19. The text string is stored in non-volatile memory." ::= { falconInput19 6 } falconInput19HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 19 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 19. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput19 7 } falconInput19HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 19 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 19. The HighLimit variable is stored in non-volatile memory." ::= { falconInput19 8 } falconInput19LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 19 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 19. The LowLimit variable is stored in non-volatile memory." ::= { falconInput19 9 } falconInput19LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 19 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 19. The LowLimit variable is stored in non-volatile memory." ::= { falconInput19 10 } falconInput19RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput19 11 } falconInput19Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput19 12 } falconInput19Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput19 13 } falconInput19Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 19." ::= { falconInput19 14 } falconInput19DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 19. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput19 15 } falconInput20 OBJECT IDENTIFIER ::= { falconInputs 20 } falconInput20State OBJECT-TYPE SYNTAX INTEGER { notInstalled(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number 20. When a sensor is connected to Input 20 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 20 set State to notInstalled(1) to indicate that the value of falconReading1 may not be valid. This variable is stored in non-volatile memory." ::= { falconInput20 1 } falconInput20Reading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 20. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInput20 2 } falconInput20Gain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 20 to obtain the value of the Input20 variable. The gain variable is stored in non-volatile memory." ::= { falconInput20 3 } falconInput20Offset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 20 to obtain the value of the Input20 variable. The Offset variable is stored in non-volatile memory." ::= { falconInput20 4 } falconInput20Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 20. The text string is stored in non-volatile memory." ::= { falconInput20 5 } falconInput20UOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 20. The text string is stored in non-volatile memory." ::= { falconInput20 6 } falconInput20HighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 20 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 20. The HighLimit2 variable is stored in non-volatile memory." ::= { falconInput20 7 } falconInput20HighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 20 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 20. The HighLimit variable is stored in non-volatile memory." ::= { falconInput20 8 } falconInput20LowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 20 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 20. The LowLimit variable is stored in non-volatile memory." ::= { falconInput20 9 } falconInput20LowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When input 20 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 20. The LowLimit variable is stored in non-volatile memory." ::= { falconInput20 10 } falconInput20RlyControl OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2 on a high alarm, set the 2nd bit (2). To set K1 on a low alarm, set the 3rd bit (4). To set K2 on a low alarm, set the 4th bit (8). To set K1 on a digital alarm, set the 1st bit (1). To set K2 on a digital alarm, set the 2nd bit (2). For no action. set this value to 0. The range of this setting is 0..15. This variable is stored in non-volatile memory." ::= { falconInput20 11 } falconInput20Delay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile memory." ::= { falconInput20 12 } falconInput20Hysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in non-volatile memory." ::= { falconInput20 13 } falconInput20Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for input 20." ::= { falconInput20 14 } falconInput20DigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Input Number 20. This string is used for digital off text. The text string is stored in non-volatile memory." ::= { falconInput20 15 } falconOutputs OBJECT IDENTIFIER ::= { falconMIB 4 } falconRelay1 OBJECT IDENTIFIER ::= { falconOutputs 1 } falconRelay1State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 1. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay1 1 } falconRelay1Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 1." ::= { falconRelay1 2 } falconRelay1Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 1. The text string is stored in non-volatile memory." ::= { falconRelay1 3 } falconRelay1Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay1 4 } falconRelay1Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 1." ::= { falconRelay1 5 } falconRelay2 OBJECT IDENTIFIER ::= { falconOutputs 2 } falconRelay2State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 2. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay2 1 } falconRelay2Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 2." ::= { falconRelay2 2 } falconRelay2Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 2. The text string is stored in non-volatile memory." ::= { falconRelay2 3 } falconRelay2Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay2 4 } falconRelay2Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 2." ::= { falconRelay2 5 } falconRelay3 OBJECT IDENTIFIER ::= { falconOutputs 3 } falconRelay3State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 3. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay3 1 } falconRelay3Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 3." ::= { falconRelay3 2 } falconRelay3Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 3. The text string is stored in non-volatile memory." ::= { falconRelay3 3 } falconRelay3Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay3 4 } falconRelay3Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 3." ::= { falconRelay3 5 } falconRelay4 OBJECT IDENTIFIER ::= { falconOutputs 4 } falconRelay4State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 4. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay4 1 } falconRelay4Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 4." ::= { falconRelay4 2 } falconRelay4Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 4. The text string is stored in non-volatile memory." ::= { falconRelay4 3 } falconRelay4Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay4 4 } falconRelay4Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 4." ::= { falconRelay4 5 } falconRelay5 OBJECT IDENTIFIER ::= { falconOutputs 5 } falconRelay5State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 5. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay5 1 } falconRelay5Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 5." ::= { falconRelay5 2 } falconRelay5Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 5. The text string is stored in non-volatile memory." ::= { falconRelay5 3 } falconRelay5Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay5 4 } falconRelay5Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 5." ::= { falconRelay5 5 } falconRelay6 OBJECT IDENTIFIER ::= { falconOutputs 6 } falconRelay6State OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Relay Number 6. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad. This variable is stored in non-volatile memory." ::= { falconRelay6 1 } falconRelay6Status OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for relay 6." ::= { falconRelay6 2 } falconRelay6Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with Relay Number 6. The text string is stored in non-volatile memory." ::= { falconRelay6 3 } falconRelay6Time OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelay6 4 } falconRelay6Schedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for relay 6." ::= { falconRelay6 5 } falconAlarms OBJECT IDENTIFIER ::= { falconMIB 5 } falconAlarmsPresent OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The present number of active alarm conditions." ::= { falconAlarms 1 } falconAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with falconAlarmId equal to 1, and increments the value of falconAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of falconAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because falconAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), falconAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of falconAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of falconAlarmsPresent." ::= { falconAlarms 2 } falconAlarmEntry OBJECT-TYPE SYNTAX FalconAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular alarm." INDEX { falconAlarmId } ::= { falconAlarmTable 1 } FalconAlarmEntry ::= SEQUENCE { falconAlarmId PositiveInteger, falconAlarmDescr OBJECT IDENTIFIER } falconAlarmId OBJECT-TYPE SYNTAX PositiveInteger ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant." ::= { falconAlarmEntry 1 } falconAlarmDescr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition." ::= { falconAlarmEntry 2 } -- -- Well known alarm conditions. -- falconWellKnownAlarms OBJECT IDENTIFIER ::= { falconAlarms 3 } falconInput1HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 1 has reached the high limit value." ::= { falconWellKnownAlarms 1 } falconInput1LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 1 has reached the low limit value." ::= { falconWellKnownAlarms 2 } falconInput1High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 1 has reached the high limit value." ::= { falconWellKnownAlarms 3 } falconInput1Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 1 has reached the low limit value." ::= { falconWellKnownAlarms 4 } falconInput2HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 2 has reached the high limit value." ::= { falconWellKnownAlarms 5 } falconInput2LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 2 has reached the low limit value." ::= { falconWellKnownAlarms 6 } falconInput2High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 2 has reached the high limit value." ::= { falconWellKnownAlarms 7 } falconInput2Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 2 has reached the low limit value." ::= { falconWellKnownAlarms 8 } falconInput3HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 3 has reached the high limit value." ::= { falconWellKnownAlarms 9 } falconInput3LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 3 has reached the low limit value." ::= { falconWellKnownAlarms 10 } falconInput3High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 3 has reached the high limit value." ::= { falconWellKnownAlarms 11 } falconInput3Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 3 has reached the low limit value." ::= { falconWellKnownAlarms 12 } falconInput4HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 4 has reached the high limit value." ::= { falconWellKnownAlarms 13 } falconInput4LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 4 has reached the low limit value." ::= { falconWellKnownAlarms 14 } falconInput4High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 4 has reached the high limit value." ::= { falconWellKnownAlarms 15 } falconInput4Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 4 has reached the low limit value." ::= { falconWellKnownAlarms 16 } falconInput5HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 5 has reached the high limit value." ::= { falconWellKnownAlarms 17 } falconInput5LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 5 has reached the low limit value." ::= { falconWellKnownAlarms 18 } falconInput5High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 5 has reached the high limit value." ::= { falconWellKnownAlarms 19 } falconInput5Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 5 has reached the low limit value." ::= { falconWellKnownAlarms 20 } falconInput6HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 6 has reached the high limit value." ::= { falconWellKnownAlarms 21 } falconInput6LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 6 has reached the low limit value." ::= { falconWellKnownAlarms 22 } falconInput6High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 6 has reached the high limit value." ::= { falconWellKnownAlarms 23 } falconInput6Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 6 has reached the low limit value." ::= { falconWellKnownAlarms 24 } falconInput7HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 7 has reached the high limit value." ::= { falconWellKnownAlarms 25 } falconInput7LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 7 has reached the low limit value." ::= { falconWellKnownAlarms 26 } falconInput7High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 7 has reached the high limit value." ::= { falconWellKnownAlarms 27 } falconInput7Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 7 has reached the low limit value." ::= { falconWellKnownAlarms 28 } falconInput8HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 8 has reached the high limit value." ::= { falconWellKnownAlarms 29 } falconInput8LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 8 has reached the low limit value." ::= { falconWellKnownAlarms 30 } falconInput8High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 8 has reached the high limit value." ::= { falconWellKnownAlarms 31 } falconInput8Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 8 has reached the low limit value." ::= { falconWellKnownAlarms 32 } falconInput9HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 9 has reached the high limit value." ::= { falconWellKnownAlarms 33 } falconInput9LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 9 has reached the low limit value." ::= { falconWellKnownAlarms 34 } falconInput9High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 9 has reached the high limit value." ::= { falconWellKnownAlarms 35 } falconInput9Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 9 has reached the low limit value." ::= { falconWellKnownAlarms 36 } falconInput10HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 10 has reached the high limit value." ::= { falconWellKnownAlarms 37 } falconInput10LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 10 has reached the low limit value." ::= { falconWellKnownAlarms 38 } falconInput10High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 10 has reached the high limit value." ::= { falconWellKnownAlarms 39 } falconInput10Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 10 has reached the low limit value." ::= { falconWellKnownAlarms 40 } falconInput11HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 11 has reached the high limit value." ::= { falconWellKnownAlarms 41 } falconInput11LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 11 has reached the low limit value." ::= { falconWellKnownAlarms 42 } falconInput11High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 11 has reached the high limit value." ::= { falconWellKnownAlarms 43 } falconInput11Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 11 has reached the low limit value." ::= { falconWellKnownAlarms 44 } falconInput12HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 12 has reached the high limit value." ::= { falconWellKnownAlarms 45 } falconInput12LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 12 has reached the low limit value." ::= { falconWellKnownAlarms 46 } falconInput12High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 12 has reached the high limit value." ::= { falconWellKnownAlarms 47 } falconInput12Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 12 has reached the low limit value." ::= { falconWellKnownAlarms 48 } falconInput13HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 13 has reached the high limit value." ::= { falconWellKnownAlarms 49 } falconInput13LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 13 has reached the low limit value." ::= { falconWellKnownAlarms 50 } falconInput13High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 13 has reached the high limit value." ::= { falconWellKnownAlarms 51 } falconInput13Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 13 has reached the low limit value." ::= { falconWellKnownAlarms 52 } falconInput14HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 14 has reached the high limit value." ::= { falconWellKnownAlarms 53 } falconInput14LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 14 has reached the low limit value." ::= { falconWellKnownAlarms 54 } falconInput14High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 14 has reached the high limit value." ::= { falconWellKnownAlarms 55 } falconInput14Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 14 has reached the low limit value." ::= { falconWellKnownAlarms 56 } falconInput15HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 15 has reached the high limit value." ::= { falconWellKnownAlarms 57 } falconInput15LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 15 has reached the low limit value." ::= { falconWellKnownAlarms 58 } falconInput15High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 15 has reached the high limit value." ::= { falconWellKnownAlarms 59 } falconInput15Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 15 has reached the low limit value." ::= { falconWellKnownAlarms 60 } falconInput16HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 16 has reached the high limit value." ::= { falconWellKnownAlarms 61 } falconInput16LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 16 has reached the low limit value." ::= { falconWellKnownAlarms 62 } falconInput16High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 16 has reached the high limit value." ::= { falconWellKnownAlarms 63 } falconInput16Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 16 has reached the low limit value." ::= { falconWellKnownAlarms 64 } falconInput17HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 17 has reached the high limit value." ::= { falconWellKnownAlarms 65 } falconInput17LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 17 has reached the low limit value." ::= { falconWellKnownAlarms 66 } falconInput17High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 17 has reached the high limit value." ::= { falconWellKnownAlarms 67 } falconInput17Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 17 has reached the low limit value." ::= { falconWellKnownAlarms 68 } falconInput18HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 18 has reached the high limit value." ::= { falconWellKnownAlarms 69 } falconInput18LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 18 has reached the low limit value." ::= { falconWellKnownAlarms 70 } falconInput18High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 18 has reached the high limit value." ::= { falconWellKnownAlarms 71 } falconInput18Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 18 has reached the low limit value." ::= { falconWellKnownAlarms 72 } falconInput19HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 19 has reached the high limit value." ::= { falconWellKnownAlarms 73 } falconInput19LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 19 has reached the low limit value." ::= { falconWellKnownAlarms 74 } falconInput19High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 19 has reached the high limit value." ::= { falconWellKnownAlarms 75 } falconInput19Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 19 has reached the low limit value." ::= { falconWellKnownAlarms 76 } falconInput20HighAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 20 has reached the high limit value." ::= { falconWellKnownAlarms 77 } falconInput20LowAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 20 has reached the low limit value." ::= { falconWellKnownAlarms 78 } falconInput20High2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 20 has reached the high limit value." ::= { falconWellKnownAlarms 79 } falconInput20Low2Alarm OBJECT-IDENTITY STATUS current DESCRIPTION "The reading for sensor 20 has reached the low limit value." ::= { falconWellKnownAlarms 80 } falconInput1DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 1 has been activated." ::= { falconWellKnownAlarms 81 } falconInput2DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 2 has been activated." ::= { falconWellKnownAlarms 82 } falconInput3DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 3 has been activated." ::= { falconWellKnownAlarms 83 } falconInput4DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 4 has been activated." ::= { falconWellKnownAlarms 84 } falconInput5DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 5 has been activated." ::= { falconWellKnownAlarms 85 } falconInput6DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 6 has been activated." ::= { falconWellKnownAlarms 86 } falconInput7DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 7 has been activated." ::= { falconWellKnownAlarms 87 } falconInput8DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 8 has been activated." ::= { falconWellKnownAlarms 88 } falconInput9DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 9 has been activated." ::= { falconWellKnownAlarms 89 } falconInput10DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 10 has been activated." ::= { falconWellKnownAlarms 90 } falconInput11DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 11 has been activated." ::= { falconWellKnownAlarms 91 } falconInput12DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 12 has been activated." ::= { falconWellKnownAlarms 92 } falconInput13DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 13 has been activated." ::= { falconWellKnownAlarms 93 } falconInput14DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 14 has been activated." ::= { falconWellKnownAlarms 94 } falconInput15DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 15 has been activated." ::= { falconWellKnownAlarms 95 } falconInput16DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 16 has been activated." ::= { falconWellKnownAlarms 96 } falconInput17DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 17 has been activated." ::= { falconWellKnownAlarms 97 } falconInput18DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 18 has been activated." ::= { falconWellKnownAlarms 98 } falconInput19DigAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The digital input 19 has been activated." ::= { falconWellKnownAlarms 99 } falconOnBatteryAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The On Battery input has been activated." ::= { falconWellKnownAlarms 114 } falconLowBatteryAlarm OBJECT-IDENTITY STATUS current DESCRIPTION "The Faclon has detected a low battery condition." ::= { falconWellKnownAlarms 115 } falconTraps OBJECT IDENTIFIER ::= { falconMIB 6 } falconAlarmEntryAdded TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An AlarmEntryAdded Trap signifies that the a sensor reading has reached a high or low limit value." ::= 1 falconAlarmEntryRemoved TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An AlarmEntryAdded Trap signifies that the a sensor reading has gone below the high limit value or above the low limit value." ::= 2 falconAccessGranted TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An falconAccessGranted Trap signifies that a valid key code sequence was processed by the falcon." ::= 3 falconAccessDenied TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An falconAccessedDenied Trap signifies that an invalid key code sequence was processed by the falcon." ::= 4 falconPageUnsuccessful TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An falconPageUnsuccessful Trap signifies that an alpha numeric page could not be sent to the service." ::= 5 falconAlarmHistory OBJECT IDENTIFIER ::= { falconMIB 7 } falconAlarmHistoryEntries OBJECT-TYPE SYNTAX Gauge32 ACCESS read-only STATUS mandatory DESCRIPTION "The present number of entries in the alarm history." ::= { falconAlarmHistory 1 } falconAlarmHistoryClear OBJECT-TYPE SYNTAX INTEGER { clearBuffer(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to ClearBuffer(1) will clear the alarm history buffer. " ::= { falconAlarmHistory 2 } falconAlarmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of alarm history table entries stored in the in the non-volatile memory. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The falcon creates a row in the table each time a new alarm is detected. The falcon creates the first row with falconAlarmHistoryId equal to 1, and increments the value of falconAlarmHistoryId each time a new row is created, up to a maximum of 100. After 100 entries are created, the falcon will overwrite the earliest entry with the latest alarm. The number of rows in the table at any given time is reflected by the value of falconAlarmHistoryEntries." ::= { falconAlarmHistory 3 } falconAlarmHistoryEntry OBJECT-TYPE SYNTAX FalconAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular alarm history entry." INDEX { falconAlarmHistoryId } ::= { falconAlarmHistoryTable 1 } FalconAlarmHistoryEntry ::= SEQUENCE { falconAlarmHistoryId PositiveInteger, falconAlarmHistoryText DisplayString } falconAlarmHistoryId OBJECT-TYPE SYNTAX PositiveInteger ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant." ::= { falconAlarmHistoryEntry 1 } falconAlarmHistoryText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text desciption of the alarm history entry. Each of the strings will have the following format, AHxxx-id-type-timestamp label xxx = number entry in the table id = Alarm ID type = HIGH, LOW, ALM or RTN timestamp = MM/DD/YY HH:MM:SS Label = The label associated with the input channel These alarms are stored in non-volatile memory." ::= { falconAlarmHistoryEntry 2 } falconTrapSettings OBJECT IDENTIFIER ::= { falconMIB 8 } falconPersistantTraps OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes between persistant traps. Set this to 0 to turn off persistant traps. This value is stored in non-volatile memory." ::= { falconTrapSettings 1 } falconAlarmAcknowledge OBJECT-TYPE SYNTAX INTEGER { acknowledgeAlarms(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to AcknowledgeAlarms(1) will stop the falcon from sending persistant traps and dial out sequences." ::= { falconTrapSettings 2 } falconSchedules OBJECT IDENTIFIER ::= { falconMIB 9 } falconScheduleABeginDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The beginning day of the week for schedule A. This variable is stored in non-volatile memory." ::= { falconSchedules 1 } falconScheduleAEndDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The ending day of the week for schedule A. This variable is stored in non-volatile memory." ::= { falconSchedules 2 } falconScheduleABeginTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule A beginning time of day. Displayed as HH:MM" ::= { falconSchedules 3 } falconScheduleAEndTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule A ending time of day. Displayed as HH:MM" ::= { falconSchedules 4 } falconScheduleBBeginDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The beginning day of the week for schedule B. This variable is stored in non-volatile memory." ::= { falconSchedules 5 } falconScheduleBEndDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The ending day of the week for schedule B. This variable is stored in non-volatile memory." ::= { falconSchedules 6 } falconScheduleBBeginTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule B beginning time of day. Displayed as HH:MM" ::= { falconSchedules 7 } falconScheduleBEndTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule B ending time of day. Displayed as HH:MM" ::= { falconSchedules 8 } -- -- The falcon Extension -- falcon8 OBJECT IDENTIFIER ::= { falcon 2 } falcon8124 OBJECT IDENTIFIER ::= { falcon 3 } falcon812A4 OBJECT IDENTIFIER ::= { falcon 4 } falcon32 OBJECT IDENTIFIER ::= { falcon 5 } END