-- Title: FMS-XXXX.MIB -- Version: v7.4c -- Date: 01/15/07 -- Copyright @ 2007 RLE Technologies. All rights reserved worldwide. -- This MIB defines objects for the RLE falcon SNMP Agent. RLE-FALCON-EM-MIB DEFINITIONS ::= BEGIN IMPORTS TruthValue FROM RFC1253-MIB DisplayString FROM RFC1213-MIB OBJECT-TYPE, Gauge FROM RFC1155-SMI TRAP-TYPE FROM RFC-1215 Counter, enterprises FROM RFC1155-SMI; PositiveInteger ::= INTEGER (1..2147483647) rle OBJECT IDENTIFIER ::= { enterprises 3184 } products OBJECT IDENTIFIER ::= { rle 1 } falcon-em OBJECT IDENTIFIER ::= { products 5 } falcon-emMIB OBJECT IDENTIFIER ::= { falcon-em 1 } falconIdent OBJECT IDENTIFIER ::= { falcon-emMIB 1 } falconIdentManufacturer OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit manufacturer." ::= { falconIdent 1 } falconIdentModel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The Monitor Control Unit Model designation." ::= { falconIdent 2 } falconIdentSoftwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The falcon SNMP Agent software version." ::= { falconIdent 3 } falconIdentSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to MIB definitions specific to the particular Monitor Unit being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value." ::= { falconIdent 4 } falconOptionCards OBJECT IDENTIFIER ::= { falconIdent 5 } falconOptionCard1 OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), analog12input12relay(1), digital12input12relay(2), digital24input(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Option slot #1." ::= { falconOptionCards 1 } falconOptionCard2 OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), analog12input12relay(1), digital12input12relay(2), digital24input(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Option slot #2." ::= { falconOptionCards 2 } falconOptionCard3 OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), analog12input12relay(1), digital12input12relay(2), digital24input(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Option slot #3." ::= { falconOptionCards 3 } falconOptionCard4 OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), analog12input12relay(1), digital12input12relay(2), digital24input(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Option slot #4." ::= { falconOptionCards 4 } falconSystem OBJECT IDENTIFIER ::= { falcon-emMIB 2 } falconSystemSettings OBJECT IDENTIFIER ::= { falconSystem 1 } falconClock OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon internal clock settings. Displayed as MM/DD/YY HH:MM:SS" ::= { falconSystemSettings 1 } falconDoorAlarmBypass OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The falcon door alarm bypass switch. This allows the alarm to be bypassed upon valid keypad access. Zero disables this, or use 1 thru 8 for the corresponding falcon input." ::= { falconSystemSettings 2 } falconInputVoltage OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The falcon input voltage (DC Power)." ::= { falconSystemSettings 3 } falconLowBatteryThreshold OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The low voltage trip point for the low battery alarm. When the input voltage goes below this voltage, the Low Battery alarm is set." ::= { falconSystemSettings 4 } falconAnalogAverage OBJECT-TYPE SYNTAX INTEGER (0..60) ACCESS read-write STATUS mandatory DESCRIPTION "This is the analog averaging duration in seconds. The analog input readings are averaged for this time period before updating. This value must be set to 1,2,3,4,5,6,10,15,20,30 or 60 seconds." ::= { falconSystemSettings 5 } falconPagerStatusString OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The falcon last page status char string." ::= { falconSystemSettings 6 } falconWebUser OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The web user who made the last configuration changes." ::= { falconSystemSettings 7 } falconKeypad OBJECT IDENTIFIER ::= { falconSystem 2 } falconKeypadUsers OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of keypad users allowed on this system." ::= { falconKeypad 1 } falconKeypadUsersTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconKeypadUserEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon keypad users. The number of users is given by the value of falconKeypadUsers." ::= { falconKeypad 2 } falconKeypadUserEntry OBJECT-TYPE SYNTAX FalconKeypadUserEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon keypad user configuration." INDEX { falconKeypadUserIndex } ::= { falconKeypadUsersTable 1 } FalconKeypadUserEntry ::= SEQUENCE { falconKeypadUserIndex INTEGER, falconKeypadCode DisplayString, falconKeypadName DisplayString } falconKeypadUserIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each keypad user. Its value ranges between 1 and the value of falconKeypadUsers." ::= { falconKeypadUserEntry 1 } falconKeypadCode OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access code for user #X. This can be up to six numeric characters." ::= { falconKeypadUserEntry 2 } falconKeypadName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The falcon keypad access name for user #X. This can be up to 20 characters." ::= { falconKeypadUserEntry 3 } falconInputs OBJECT IDENTIFIER ::= { falcon-emMIB 3 } falconInputPorts OBJECT IDENTIFIER ::= { falconInputs 1 } falconNumberOfInputPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of input ports available on this system." ::= { falconInputPorts 1 } falconInputTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon input port status and configuration. The number of input ports is given by the value of falconNumberOfInputPorts." ::= { falconInputPorts 2 } falconInputEntry OBJECT-TYPE SYNTAX FalconInputEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon input port data and configuration." INDEX { falconInputIndex } ::= { falconInputTable 1 } FalconInputEntry ::= SEQUENCE { falconInputIndex INTEGER, falconInputType INTEGER, falconInputState INTEGER, falconInputReading INTEGER, falconInputGain INTEGER, falconInputOffset INTEGER, falconInputLabel DisplayString, falconInputUOM DisplayString, falconInputHighLimit2 INTEGER, falconInputHighLimit INTEGER, falconInputLowLimit INTEGER, falconInputLowLimit2 INTEGER, falconInputDelay INTEGER, falconInputHysteresis INTEGER, falconInputSchedule INTEGER, falconInputDigOffLabel DisplayString } falconInputIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each input port. Its value ranges between 1 and the value of falconNumberOfInputPorts." ::= { falconInputEntry 1 } falconInputType OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), analog(1), digital(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The installed hardware for Input Number X. If this value is notInstalled(0) then this input is not physically installed in the falcon." ::= { falconInputEntry 2 } falconInputState OBJECT-TYPE SYNTAX INTEGER { notInstalled(0), notConfigured(1), analog4to20Installed(2), digitalNOInstalled(3), digitalNCInstalled(4), digitalSTInstalled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of Input Number X. When a sensor is connected to Input 1 set State to installed(2) to indicate that the value of falconReading1 is valid. When no sensor is connected to Input 1 set State to notConfigured(1) to indicate that the value of falconInputReading may not be valid." ::= { falconInputEntry 3 } falconInputReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor. If the input is digital, the reading will be 1 (active) or 0 (inactive)" ::= { falconInputEntry 4 } falconInputGain OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor to obtain the value of the Input variable." ::= { falconInputEntry 5 } falconInputOffset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from the Input Sensor to obtain the value of the Input variable." ::= { falconInputEntry 6 } falconInputLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with the Input port." ::= { falconInputEntry 7 } falconInputUOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with the Input port." ::= { falconInputEntry 8 } falconInputHighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the input port reaches or exceeds this value a trap will be generated signifying a high alarm condition at this sensor." ::= { falconInputEntry 9 } falconInputHighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the input port reaches or exceeds this value a trap will be generated signifying a high alarm condition at this sensor." ::= { falconInputEntry 10 } falconInputLowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the input port reaches or goes below this value a trap will be generated signifying a low alarm condition at this sensor." ::= { falconInputEntry 11 } falconInputLowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the input port reaches or goes below this value a trap will be generated signifying a low alarm condition at this sensor." ::= { falconInputEntry 12 } falconInputDelay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600." ::= { falconInputEntry 13 } falconInputHysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear." ::= { falconInputEntry 14 } falconInputSchedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for the input port." ::= { falconInputEntry 15 } falconInputDigOffLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with the input port. This string is used for digital off text." ::= { falconInputEntry 16 } falconTHSensors OBJECT IDENTIFIER ::= { falconInputs 2 } falconTempSensors OBJECT IDENTIFIER ::= { falconTHSensors 1 } falconNumberOfTempSensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of internal temperature sensors available on this system." ::= { falconTempSensors 1 } falconTSTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon internal temperature sensor status and configuration. The number of sensors is given by the value of falconNumberOfTempSensors." ::= { falconTempSensors 2 } falconTSEntry OBJECT-TYPE SYNTAX FalconTSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon internal temperature sensor data and configuration." INDEX { falconTSIndex } ::= { falconTSTable 1 } FalconTSEntry ::= SEQUENCE { falconTSIndex INTEGER, falconTemperatureSensorState INTEGER, falconTemperatureSensorReading INTEGER, falconTemperatureSensorOffset INTEGER, falconTemperatureSensorLabel DisplayString, falconTemperatureSensorUOM DisplayString, falconTemperatureSensorHighLimit2 INTEGER, falconTemperatureSensorHighLimit INTEGER, falconTemperatureSensorLowLimit INTEGER, falconTemperatureSensorLowLimit2 INTEGER, falconTemperatureSensorDelay INTEGER, falconTemperatureSensorHysteresis INTEGER, falconTemperatureSensorSchedule INTEGER } falconTSIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each internal temperature sensor. Its value ranges between 1 and the value of falconNumberOfTempSensors." ::= { falconTSEntry 1 } falconTemperatureSensorState OBJECT-TYPE SYNTAX INTEGER { degF(0), degC(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of the internal temperature sensor." ::= { falconTSEntry 2 } falconTemperatureSensorReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal temperature sensor." ::= { falconTSEntry 3 } falconTemperatureSensorOffset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from internal temperature sensor to obtain the value of the TemperatureSensor variable." ::= { falconTSEntry 4 } falconTemperatureSensorLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with internal temperature sensor." ::= { falconTSEntry 5 } falconTemperatureSensorUOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with internal temperature sensor." ::= { falconTSEntry 6 } falconTemperatureSensorHighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal temperature sensor reaches or exceeds this value a trap will be generated signifying a high alarm condition." ::= { falconTSEntry 7 } falconTemperatureSensorHighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal temperature sensor reaches or exceeds this value a trap will be generated signifying a high alarm condition." ::= { falconTSEntry 8 } falconTemperatureSensorLowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal temperature sensor reaches or goes below this value a trap will be generated signifying a low alarm condition." ::= { falconTSEntry 9 } falconTemperatureSensorLowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal temperature sensor reaches or goes below this value a trap will be generated signifying a low alarm condition." ::= { falconTSEntry 10 } falconTemperatureSensorDelay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600." ::= { falconTSEntry 11 } falconTemperatureSensorHysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this sensor. The reading must decrease or increase by this value before the alarm will clear." ::= { falconTSEntry 12 } falconTemperatureSensorSchedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for this sensor." ::= { falconTSEntry 13 } falconHumiditySensors OBJECT IDENTIFIER ::= { falconTHSensors 2 } falconNumberOfHumiditySensors OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of internal humidity sensors available on this system." ::= { falconHumiditySensors 1 } falconHSTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconHSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon internal humidity sensor status and configuration. The number of sensors is given by the value of falconNumberOfHumiditySensors." ::= { falconHumiditySensors 2 } falconHSEntry OBJECT-TYPE SYNTAX FalconHSEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon internal humidity sensor data and configuration." INDEX { falconHSIndex } ::= { falconHSTable 1 } FalconHSEntry ::= SEQUENCE { falconHSIndex INTEGER, falconHumiditySensorState INTEGER, falconHumiditySensorReading INTEGER, falconHumiditySensorOffset INTEGER, falconHumiditySensorLabel DisplayString, falconHumiditySensorUOM DisplayString, falconHumiditySensorHighLimit2 INTEGER, falconHumiditySensorHighLimit INTEGER, falconHumiditySensorLowLimit INTEGER, falconHumiditySensorLowLimit2 INTEGER, falconHumiditySensorDelay INTEGER, falconHumiditySensorHysteresis INTEGER, falconHumiditySensorSchedule INTEGER } falconHSIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each internal humidity sensor. Its value ranges between 1 and the value of falconNumberOfHumiditySensors." ::= { falconHSEntry 1 } falconHumiditySensorState OBJECT-TYPE SYNTAX INTEGER { RelativeHumidity(1) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of the internal humidity sensor." ::= { falconHSEntry 2 } falconHumiditySensorReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal humidity sensor." ::= { falconHSEntry 3 } falconHumiditySensorOffset OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "A correction Offset associated with the sensor variable. The value of Offset is added to the value from internal humidity sensor to obtain the value of the HumiditySensor variable." ::= { falconHSEntry 4 } falconHumiditySensorLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with internal humidity sensor." ::= { falconHSEntry 5 } falconHumiditySensorUOM OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with internal humidity sensor." ::= { falconHSEntry 6 } falconHumiditySensorHighLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal humidity sensor reaches or exceeds this value a trap will be generated signifying a high alarm condition." ::= { falconHSEntry 7 } falconHumiditySensorHighLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal humidity sensor reaches or exceeds this value a trap will be generated signifying a high alarm condition." ::= { falconHSEntry 8 } falconHumiditySensorLowLimit OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal humidity sensor reaches or goes below this value a trap will be generated signifying a low alarm condition." ::= { falconHSEntry 9 } falconHumiditySensorLowLimit2 OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "When the internal humidity sensor reaches or goes below this value a trap will be generated signifying a low alarm condition." ::= { falconHSEntry 10 } falconHumiditySensorDelay OBJECT-TYPE SYNTAX INTEGER (0..600) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds an alarm for this sensor must be present before annunication. The range of this setting is 0..600." ::= { falconHSEntry 11 } falconHumiditySensorHysteresis OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The value of alarm hysteresis for this sensor. The sensor reading must decrease or increase by this value before the alarm will clear." ::= { falconHSEntry 12 } falconHumiditySensorSchedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current alarm disable schedule for the humidity sensor." ::= { falconHSEntry 13 } falconOutputs OBJECT IDENTIFIER ::= { falcon-emMIB 4 } falconRelays OBJECT IDENTIFIER ::= { falconOutputs 1 } falconNumberOfRelays OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of output relays available on this system." ::= { falconRelays 1 } falconRelayTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon output relay status and configuration. The number of relays is given by the value of falconNumberOfRelays." ::= { falconRelays 2 } falconRelayEntry OBJECT-TYPE SYNTAX FalconRelayEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon output relay data and configuration." INDEX { falconRelayIndex } ::= { falconRelayTable 1 } FalconRelayEntry ::= SEQUENCE { falconRelayIndex INTEGER, falconRelayState INTEGER, falconRelayStatus INTEGER, falconRelayLabel DisplayString, falconRelayTime INTEGER, falconRelaySchedule INTEGER } falconRelayIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each output relay. Its value ranges between 1 and the value of falconNumberOfRelays." ::= { falconRelayEntry 1 } falconRelayState OBJECT-TYPE SYNTAX INTEGER { normallyOff(1), normallyOn(2), forceOn(3), forceOff(4), keypadControlled(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The state of use of this relay. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the keypad." ::= { falconRelayEntry 2 } falconRelayStatus OBJECT-TYPE SYNTAX INTEGER { normalOff(1), normalOn(2), forcedOn(3), forcedOff(4), keycodeActive(5), alarmedActive(6), scheduledActive(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this relay." ::= { falconRelayEntry 3 } falconRelayLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "A user-defined text string associated with this relay." ::= { falconRelayEntry 4 } falconRelayTime OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of seconds the relay will be activated. Set this to -1 for indefinitely." ::= { falconRelayEntry 5 } falconRelaySchedule OBJECT-TYPE SYNTAX INTEGER { none(0), a(1), b(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current schedule for this relay." ::= { falconRelayEntry 6 } falconAlarms OBJECT IDENTIFIER ::= { falcon-emMIB 5 } falconAlarmsPresent OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The present number of active alarm conditions." ::= { falconAlarms 1 } falconAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The agent creates the first row with falconAlarmId equal to 1, and increments the value of falconAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of falconAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse, e.g., containing entries for rows 95, 100, 101, and 203 and the entries should not be assumed to be in chronological order because falconAlarmId might have wrapped. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), falconAlarmDescr, to allow a single table to reflect well known alarms plus alarms defined by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device. No two rows will have the same value of falconAlarmDescr, since alarms define conditions. In order to meet this requirement, care should be taken in the definition of alarm conditions to insure that a system cannot enter the same condition multiple times simultaneously. The number of rows in the table at any given time is reflected by the value of falconAlarmsPresent." ::= { falconAlarms 2 } falconAlarmEntry OBJECT-TYPE SYNTAX FalconAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular alarm." INDEX { falconAlarmId } ::= { falconAlarmTable 1 } FalconAlarmEntry ::= SEQUENCE { falconAlarmId PositiveInteger, falconAlarmDescr OBJECT IDENTIFIER } falconAlarmId OBJECT-TYPE SYNTAX PositiveInteger ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant." ::= { falconAlarmEntry 1 } falconAlarmDescr OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition." ::= { falconAlarmEntry 2 } -- -- Well known alarm conditions. -- falconWellKnownAlarms OBJECT IDENTIFIER ::= { falconAlarms 3 } falconInput1DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 1 has been activated." ::= { falconWellKnownAlarms 10 } falconInput1HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 1 has reached the high limit value." ::= { falconWellKnownAlarms 11 } falconInput1LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 1 has reached the low limit value." ::= { falconWellKnownAlarms 12 } falconInput1High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 1 has reached the high limit value." ::= { falconWellKnownAlarms 13 } falconInput1Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 1 has reached the low limit value." ::= { falconWellKnownAlarms 14 } falconInput2DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 2 has been activated." ::= { falconWellKnownAlarms 20 } falconInput2HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2 has reached the high limit value." ::= { falconWellKnownAlarms 21 } falconInput2LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2 has reached the low limit value." ::= { falconWellKnownAlarms 22 } falconInput2High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2 has reached the high limit value." ::= { falconWellKnownAlarms 23 } falconInput2Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 2 has reached the low limit value." ::= { falconWellKnownAlarms 24 } falconInput3DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 3 has been activated." ::= { falconWellKnownAlarms 30 } falconInput3HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3 has reached the high limit value." ::= { falconWellKnownAlarms 31 } falconInput3LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3 has reached the low limit value." ::= { falconWellKnownAlarms 32 } falconInput3High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3 has reached the high limit value." ::= { falconWellKnownAlarms 33 } falconInput3Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 3 has reached the low limit value." ::= { falconWellKnownAlarms 34 } falconInput4DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 4 has been activated." ::= { falconWellKnownAlarms 40 } falconInput4HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4 has reached the high limit value." ::= { falconWellKnownAlarms 41 } falconInput4LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4 has reached the low limit value." ::= { falconWellKnownAlarms 42 } falconInput4High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4 has reached the high limit value." ::= { falconWellKnownAlarms 43 } falconInput4Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 4 has reached the low limit value." ::= { falconWellKnownAlarms 44 } falconInput5DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 5 has been activated." ::= { falconWellKnownAlarms 50 } falconInput5HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 5 has reached the high limit value." ::= { falconWellKnownAlarms 51 } falconInput5LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 5 has reached the low limit value." ::= { falconWellKnownAlarms 52 } falconInput5High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 5 has reached the high limit value." ::= { falconWellKnownAlarms 53 } falconInput5Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 5 has reached the low limit value." ::= { falconWellKnownAlarms 54 } falconInput6DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 6 has been activated." ::= { falconWellKnownAlarms 60 } falconInput6HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 6 has reached the high limit value." ::= { falconWellKnownAlarms 61 } falconInput6LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 6 has reached the low limit value." ::= { falconWellKnownAlarms 62 } falconInput6High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 6 has reached the high limit value." ::= { falconWellKnownAlarms 63 } falconInput6Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 6 has reached the low limit value." ::= { falconWellKnownAlarms 64 } falconInput7DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 7 has been activated." ::= { falconWellKnownAlarms 70 } falconInput7HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 7 has reached the high limit value." ::= { falconWellKnownAlarms 71 } falconInput7LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 7 has reached the low limit value." ::= { falconWellKnownAlarms 72 } falconInput7High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 7 has reached the high limit value." ::= { falconWellKnownAlarms 73 } falconInput7Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 7 has reached the low limit value." ::= { falconWellKnownAlarms 74 } falconInput8DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 8 has been activated." ::= { falconWellKnownAlarms 80 } falconInput8HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 8 has reached the high limit value." ::= { falconWellKnownAlarms 81 } falconInput8LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 8 has reached the low limit value." ::= { falconWellKnownAlarms 82 } falconInput8High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 8 has reached the high limit value." ::= { falconWellKnownAlarms 83 } falconInput8Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 8 has reached the low limit value." ::= { falconWellKnownAlarms 84 } falconInput9DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 9 has been activated." ::= { falconWellKnownAlarms 1010 } falconInput9HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 9 has reached the high limit value." ::= { falconWellKnownAlarms 1011 } falconInput9LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 9 has reached the low limit value." ::= { falconWellKnownAlarms 1012 } falconInput9High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 9 has reached the high limit value." ::= { falconWellKnownAlarms 1013 } falconInput9Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 9 has reached the low limit value." ::= { falconWellKnownAlarms 1014 } falconInput10DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 10 has been activated." ::= { falconWellKnownAlarms 1020 } falconInput10HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 10 has reached the high limit value." ::= { falconWellKnownAlarms 1021 } falconInput10LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 10 has reached the low limit value." ::= { falconWellKnownAlarms 1022 } falconInput10High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 10 has reached the high limit value." ::= { falconWellKnownAlarms 1023 } falconInput10Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 10 has reached the low limit value." ::= { falconWellKnownAlarms 1024 } falconInput11DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 11 has been activated." ::= { falconWellKnownAlarms 1030 } falconInput11HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 11 has reached the high limit value." ::= { falconWellKnownAlarms 1031 } falconInput11LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 11 has reached the low limit value." ::= { falconWellKnownAlarms 1032 } falconInput11High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 11 has reached the high limit value." ::= { falconWellKnownAlarms 1033 } falconInput11Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 11 has reached the low limit value." ::= { falconWellKnownAlarms 1034 } falconInput12DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 12 has been activated." ::= { falconWellKnownAlarms 1040 } falconInput12HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 12 has reached the high limit value." ::= { falconWellKnownAlarms 1041 } falconInput12LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 12 has reached the low limit value." ::= { falconWellKnownAlarms 1042 } falconInput12High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 12 has reached the high limit value." ::= { falconWellKnownAlarms 1043 } falconInput12Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 12 has reached the low limit value." ::= { falconWellKnownAlarms 1044 } falconInput13DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 13 has been activated." ::= { falconWellKnownAlarms 1050 } falconInput13HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 13 has reached the high limit value." ::= { falconWellKnownAlarms 1051 } falconInput13LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 13 has reached the low limit value." ::= { falconWellKnownAlarms 1052 } falconInput13High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 13 has reached the high limit value." ::= { falconWellKnownAlarms 1053 } falconInput13Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 13 has reached the low limit value." ::= { falconWellKnownAlarms 1054 } falconInput14DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 14 has been activated." ::= { falconWellKnownAlarms 1060 } falconInput14HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 14 has reached the high limit value." ::= { falconWellKnownAlarms 1061 } falconInput14LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 14 has reached the low limit value." ::= { falconWellKnownAlarms 1062 } falconInput14High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 14 has reached the high limit value." ::= { falconWellKnownAlarms 1063 } falconInput14Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 14 has reached the low limit value." ::= { falconWellKnownAlarms 1064 } falconInput15DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 15 has been activated." ::= { falconWellKnownAlarms 1070 } falconInput15HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 15 has reached the high limit value." ::= { falconWellKnownAlarms 1071 } falconInput15LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 15 has reached the low limit value." ::= { falconWellKnownAlarms 1072 } falconInput15High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 15 has reached the high limit value." ::= { falconWellKnownAlarms 1073 } falconInput15Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 15 has reached the low limit value." ::= { falconWellKnownAlarms 1074 } falconInput16DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 16 has been activated." ::= { falconWellKnownAlarms 1080 } falconInput16HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 16 has reached the high limit value." ::= { falconWellKnownAlarms 1081 } falconInput16LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 16 has reached the low limit value." ::= { falconWellKnownAlarms 1082 } falconInput16High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 16 has reached the high limit value." ::= { falconWellKnownAlarms 1083 } falconInput16Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 16 has reached the low limit value." ::= { falconWellKnownAlarms 1084 } falconInput17DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 17 has been activated." ::= { falconWellKnownAlarms 1090 } falconInput17HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 17 has reached the high limit value." ::= { falconWellKnownAlarms 1091 } falconInput17LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 17 has reached the low limit value." ::= { falconWellKnownAlarms 1092 } falconInput17High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 17 has reached the high limit value." ::= { falconWellKnownAlarms 1093 } falconInput17Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 17 has reached the low limit value." ::= { falconWellKnownAlarms 1094 } falconInput18DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 18 has been activated." ::= { falconWellKnownAlarms 1100 } falconInput18HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 18 has reached the high limit value." ::= { falconWellKnownAlarms 1101 } falconInput18LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 18 has reached the low limit value." ::= { falconWellKnownAlarms 1102 } falconInput18High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 18 has reached the high limit value." ::= { falconWellKnownAlarms 1103 } falconInput18Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 18 has reached the low limit value." ::= { falconWellKnownAlarms 1104 } falconInput19DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 19 has been activated." ::= { falconWellKnownAlarms 1110 } falconInput19HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 19 has reached the high limit value." ::= { falconWellKnownAlarms 1111 } falconInput19LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 19 has reached the low limit value." ::= { falconWellKnownAlarms 1112 } falconInput19High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 19 has reached the high limit value." ::= { falconWellKnownAlarms 1113 } falconInput19Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 19 has reached the low limit value." ::= { falconWellKnownAlarms 1114 } falconInput20DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 20 has been activated." ::= { falconWellKnownAlarms 1120 } falconInput20HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 20 has reached the high limit value." ::= { falconWellKnownAlarms 1121 } falconInput20LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 20 has reached the low limit value." ::= { falconWellKnownAlarms 1122 } falconInput20High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 20 has reached the high limit value." ::= { falconWellKnownAlarms 1123 } falconInput20Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 20 has reached the low limit value." ::= { falconWellKnownAlarms 1124 } falconInput21DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 21 has been activated." ::= { falconWellKnownAlarms 1130 } falconInput22DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 22 has been activated." ::= { falconWellKnownAlarms 1140 } falconInput23DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 23 has been activated." ::= { falconWellKnownAlarms 1150 } falconInput24DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 24 has been activated." ::= { falconWellKnownAlarms 1160 } falconInput25DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 25 has been activated." ::= { falconWellKnownAlarms 1170 } falconInput26DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 26 has been activated." ::= { falconWellKnownAlarms 1180 } falconInput27DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 27 has been activated." ::= { falconWellKnownAlarms 1190 } falconInput28DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 28 has been activated." ::= { falconWellKnownAlarms 1200 } falconInput29DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 29 has been activated." ::= { falconWellKnownAlarms 1210 } falconInput30DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 30 has been activated." ::= { falconWellKnownAlarms 1220 } falconInput31DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 31 has been activated." ::= { falconWellKnownAlarms 1230 } falconInput32DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 32 has been activated." ::= { falconWellKnownAlarms 1240 } falconInput33DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 33 has been activated." ::= { falconWellKnownAlarms 2010 } falconInput33HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 33 has reached the high limit value." ::= { falconWellKnownAlarms 2011 } falconInput33LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 33 has reached the low limit value." ::= { falconWellKnownAlarms 2012 } falconInput33High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 33 has reached the high limit value." ::= { falconWellKnownAlarms 2013 } falconInput33Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 33 has reached the low limit value." ::= { falconWellKnownAlarms 2014 } falconInput34DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 34 has been activated." ::= { falconWellKnownAlarms 2020 } falconInput34HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 34 has reached the high limit value." ::= { falconWellKnownAlarms 2021 } falconInput34LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 34 has reached the low limit value." ::= { falconWellKnownAlarms 2022 } falconInput34High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 34 has reached the high limit value." ::= { falconWellKnownAlarms 2023 } falconInput34Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 34 has reached the low limit value." ::= { falconWellKnownAlarms 2024 } falconInput35DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 35 has been activated." ::= { falconWellKnownAlarms 2030 } falconInput35HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 35 has reached the high limit value." ::= { falconWellKnownAlarms 2031 } falconInput35LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 35 has reached the low limit value." ::= { falconWellKnownAlarms 2032 } falconInput35High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 35 has reached the high limit value." ::= { falconWellKnownAlarms 2033 } falconInput35Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 35 has reached the low limit value." ::= { falconWellKnownAlarms 2034 } falconInput36DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 36 has been activated." ::= { falconWellKnownAlarms 2040 } falconInput36HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 36 has reached the high limit value." ::= { falconWellKnownAlarms 2041 } falconInput36LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 36 has reached the low limit value." ::= { falconWellKnownAlarms 2042 } falconInput36High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 36 has reached the high limit value." ::= { falconWellKnownAlarms 2043 } falconInput36Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 36 has reached the low limit value." ::= { falconWellKnownAlarms 2044 } falconInput37DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 37 has been activated." ::= { falconWellKnownAlarms 2050 } falconInput37HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 37 has reached the high limit value." ::= { falconWellKnownAlarms 2051 } falconInput37LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 37 has reached the low limit value." ::= { falconWellKnownAlarms 2052 } falconInput37High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 37 has reached the high limit value." ::= { falconWellKnownAlarms 2053 } falconInput37Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 37 has reached the low limit value." ::= { falconWellKnownAlarms 2054 } falconInput38DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 38 has been activated." ::= { falconWellKnownAlarms 2060 } falconInput38HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 38 has reached the high limit value." ::= { falconWellKnownAlarms 2061 } falconInput38LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 38 has reached the low limit value." ::= { falconWellKnownAlarms 2062 } falconInput38High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 38 has reached the high limit value." ::= { falconWellKnownAlarms 2063 } falconInput38Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 38 has reached the low limit value." ::= { falconWellKnownAlarms 2064 } falconInput39DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 39 has been activated." ::= { falconWellKnownAlarms 2070 } falconInput39HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 39 has reached the high limit value." ::= { falconWellKnownAlarms 2071 } falconInput39LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 39 has reached the low limit value." ::= { falconWellKnownAlarms 2072 } falconInput39High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 39 has reached the high limit value." ::= { falconWellKnownAlarms 2073 } falconInput39Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 39 has reached the low limit value." ::= { falconWellKnownAlarms 2074 } falconInput40DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 40 has been activated." ::= { falconWellKnownAlarms 2080 } falconInput40HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 40 has reached the high limit value." ::= { falconWellKnownAlarms 2081 } falconInput40LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 40 has reached the low limit value." ::= { falconWellKnownAlarms 2082 } falconInput40High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 40 has reached the high limit value." ::= { falconWellKnownAlarms 2083 } falconInput40Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 40 has reached the low limit value." ::= { falconWellKnownAlarms 2084 } falconInput41DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 41 has been activated." ::= { falconWellKnownAlarms 2090 } falconInput41HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 41 has reached the high limit value." ::= { falconWellKnownAlarms 2091 } falconInput41LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 41 has reached the low limit value." ::= { falconWellKnownAlarms 2092 } falconInput41High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 41 has reached the high limit value." ::= { falconWellKnownAlarms 2093 } falconInput41Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 41 has reached the low limit value." ::= { falconWellKnownAlarms 2094 } falconInput42DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 42 has been activated." ::= { falconWellKnownAlarms 2100 } falconInput42HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 42 has reached the high limit value." ::= { falconWellKnownAlarms 2101 } falconInput42LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 42 has reached the low limit value." ::= { falconWellKnownAlarms 2102 } falconInput42High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 42 has reached the high limit value." ::= { falconWellKnownAlarms 2103 } falconInput42Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 42 has reached the low limit value." ::= { falconWellKnownAlarms 2104 } falconInput43DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 43 has been activated." ::= { falconWellKnownAlarms 2110 } falconInput43HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 43 has reached the high limit value." ::= { falconWellKnownAlarms 2111 } falconInput43LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 43 has reached the low limit value." ::= { falconWellKnownAlarms 2112 } falconInput43High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 43 has reached the high limit value." ::= { falconWellKnownAlarms 2113 } falconInput43Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 43 has reached the low limit value." ::= { falconWellKnownAlarms 2114 } falconInput44DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 44 has been activated." ::= { falconWellKnownAlarms 2120 } falconInput44HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 44 has reached the high limit value." ::= { falconWellKnownAlarms 2121 } falconInput44LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 44 has reached the low limit value." ::= { falconWellKnownAlarms 2122 } falconInput44High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 44 has reached the high limit value." ::= { falconWellKnownAlarms 2123 } falconInput44Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 44 has reached the low limit value." ::= { falconWellKnownAlarms 2124 } falconInput45DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 45 has been activated." ::= { falconWellKnownAlarms 2130 } falconInput46DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 46 has been activated." ::= { falconWellKnownAlarms 2140 } falconInput47DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 47 has been activated." ::= { falconWellKnownAlarms 2150 } falconInput48DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 48 has been activated." ::= { falconWellKnownAlarms 2160 } falconInput49DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 49 has been activated." ::= { falconWellKnownAlarms 2170 } falconInput50DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 50 has been activated." ::= { falconWellKnownAlarms 2180 } falconInput51DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 51 has been activated." ::= { falconWellKnownAlarms 2190 } falconInput52DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 52 has been activated." ::= { falconWellKnownAlarms 2200 } falconInput53DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 53 has been activated." ::= { falconWellKnownAlarms 2210 } falconInput54DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 54 has been activated." ::= { falconWellKnownAlarms 2220 } falconInput55DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 55 has been activated." ::= { falconWellKnownAlarms 2230 } falconInput56DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 56 has been activated." ::= { falconWellKnownAlarms 2240 } falconInput57DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 57 has been activated." ::= { falconWellKnownAlarms 3010 } falconInput57HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 57 has reached the high limit value." ::= { falconWellKnownAlarms 3011 } falconInput57LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 57 has reached the low limit value." ::= { falconWellKnownAlarms 3012 } falconInput57High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 57 has reached the high limit value." ::= { falconWellKnownAlarms 3013 } falconInput57Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 57 has reached the low limit value." ::= { falconWellKnownAlarms 3014 } falconInput58DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 58 has been activated." ::= { falconWellKnownAlarms 3020 } falconInput58HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 58 has reached the high limit value." ::= { falconWellKnownAlarms 3021 } falconInput58LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 58 has reached the low limit value." ::= { falconWellKnownAlarms 3022 } falconInput58High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 58 has reached the high limit value." ::= { falconWellKnownAlarms 3023 } falconInput58Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 58 has reached the low limit value." ::= { falconWellKnownAlarms 3024 } falconInput59DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 59 has been activated." ::= { falconWellKnownAlarms 3030 } falconInput59HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 59 has reached the high limit value." ::= { falconWellKnownAlarms 3031 } falconInput59LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 59 has reached the low limit value." ::= { falconWellKnownAlarms 3032 } falconInput59High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 59 has reached the high limit value." ::= { falconWellKnownAlarms 3033 } falconInput59Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 59 has reached the low limit value." ::= { falconWellKnownAlarms 3034 } falconInput60DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 60 has been activated." ::= { falconWellKnownAlarms 3040 } falconInput60HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 60 has reached the high limit value." ::= { falconWellKnownAlarms 3041 } falconInput60LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 60 has reached the low limit value." ::= { falconWellKnownAlarms 3042 } falconInput60High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 60 has reached the high limit value." ::= { falconWellKnownAlarms 3043 } falconInput60Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 60 has reached the low limit value." ::= { falconWellKnownAlarms 3044 } falconInput61DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 61 has been activated." ::= { falconWellKnownAlarms 3050 } falconInput61HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 61 has reached the high limit value." ::= { falconWellKnownAlarms 3051 } falconInput61LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 61 has reached the low limit value." ::= { falconWellKnownAlarms 3052 } falconInput61High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 61 has reached the high limit value." ::= { falconWellKnownAlarms 3053 } falconInput61Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 61 has reached the low limit value." ::= { falconWellKnownAlarms 3054 } falconInput62DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 62 has been activated." ::= { falconWellKnownAlarms 3060 } falconInput62HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 62 has reached the high limit value." ::= { falconWellKnownAlarms 3061 } falconInput62LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 62 has reached the low limit value." ::= { falconWellKnownAlarms 3062 } falconInput62High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 62 has reached the high limit value." ::= { falconWellKnownAlarms 3063 } falconInput62Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 62 has reached the low limit value." ::= { falconWellKnownAlarms 3064 } falconInput63DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 63 has been activated." ::= { falconWellKnownAlarms 3070 } falconInput63HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 63 has reached the high limit value." ::= { falconWellKnownAlarms 3071 } falconInput63LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 63 has reached the low limit value." ::= { falconWellKnownAlarms 3072 } falconInput63High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 63 has reached the high limit value." ::= { falconWellKnownAlarms 3073 } falconInput63Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 63 has reached the low limit value." ::= { falconWellKnownAlarms 3074 } falconInput64DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 64 has been activated." ::= { falconWellKnownAlarms 3080 } falconInput64HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 64 has reached the high limit value." ::= { falconWellKnownAlarms 3081 } falconInput64LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 64 has reached the low limit value." ::= { falconWellKnownAlarms 3082 } falconInput64High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 64 has reached the high limit value." ::= { falconWellKnownAlarms 3083 } falconInput64Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 64 has reached the low limit value." ::= { falconWellKnownAlarms 3084 } falconInput65DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 65 has been activated." ::= { falconWellKnownAlarms 3090 } falconInput65HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 65 has reached the high limit value." ::= { falconWellKnownAlarms 3091 } falconInput65LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 65 has reached the low limit value." ::= { falconWellKnownAlarms 3092 } falconInput65High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 65 has reached the high limit value." ::= { falconWellKnownAlarms 3093 } falconInput65Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 65 has reached the low limit value." ::= { falconWellKnownAlarms 3094 } falconInput66DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 66 has been activated." ::= { falconWellKnownAlarms 3100 } falconInput66HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 66 has reached the high limit value." ::= { falconWellKnownAlarms 3101 } falconInput66LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 66 has reached the low limit value." ::= { falconWellKnownAlarms 3102 } falconInput66High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 66 has reached the high limit value." ::= { falconWellKnownAlarms 3103 } falconInput66Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 66 has reached the low limit value." ::= { falconWellKnownAlarms 3104 } falconInput67DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 67 has been activated." ::= { falconWellKnownAlarms 3110 } falconInput67HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 67 has reached the high limit value." ::= { falconWellKnownAlarms 3111 } falconInput67LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 67 has reached the low limit value." ::= { falconWellKnownAlarms 3112 } falconInput67High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 67 has reached the high limit value." ::= { falconWellKnownAlarms 3113 } falconInput67Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 67 has reached the low limit value." ::= { falconWellKnownAlarms 3114 } falconInput68DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 68 has been activated." ::= { falconWellKnownAlarms 3120 } falconInput68HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 68 has reached the high limit value." ::= { falconWellKnownAlarms 3121 } falconInput68LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 68 has reached the low limit value." ::= { falconWellKnownAlarms 3122 } falconInput68High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 68 has reached the high limit value." ::= { falconWellKnownAlarms 3123 } falconInput68Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 68 has reached the low limit value." ::= { falconWellKnownAlarms 3124 } falconInput69DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 69 has been activated." ::= { falconWellKnownAlarms 3130 } falconInput70DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 70 has been activated." ::= { falconWellKnownAlarms 3140 } falconInput71DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 71 has been activated." ::= { falconWellKnownAlarms 3150 } falconInput72DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 72 has been activated." ::= { falconWellKnownAlarms 3160 } falconInput73DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 73 has been activated." ::= { falconWellKnownAlarms 3170 } falconInput74DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 74 has been activated." ::= { falconWellKnownAlarms 3180 } falconInput75DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 75 has been activated." ::= { falconWellKnownAlarms 3190 } falconInput76DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 76 has been activated." ::= { falconWellKnownAlarms 3200 } falconInput77DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 77 has been activated." ::= { falconWellKnownAlarms 3210 } falconInput78DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 78 has been activated." ::= { falconWellKnownAlarms 3220 } falconInput79DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 79 has been activated." ::= { falconWellKnownAlarms 3230 } falconInput80DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 80 has been activated." ::= { falconWellKnownAlarms 3240 } falconInput81DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 81 has been activated." ::= { falconWellKnownAlarms 4010 } falconInput81HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 81 has reached the high limit value." ::= { falconWellKnownAlarms 4011 } falconInput81LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 81 has reached the low limit value." ::= { falconWellKnownAlarms 4012 } falconInput81High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 81 has reached the high limit value." ::= { falconWellKnownAlarms 4013 } falconInput81Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 81 has reached the low limit value." ::= { falconWellKnownAlarms 4014 } falconInput82DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 82 has been activated." ::= { falconWellKnownAlarms 4020 } falconInput82HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 82 has reached the high limit value." ::= { falconWellKnownAlarms 4021 } falconInput82LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 82 has reached the low limit value." ::= { falconWellKnownAlarms 4022 } falconInput82High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 82 has reached the high limit value." ::= { falconWellKnownAlarms 4023 } falconInput82Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 82 has reached the low limit value." ::= { falconWellKnownAlarms 4024 } falconInput83DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 83 has been activated." ::= { falconWellKnownAlarms 4030 } falconInput83HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 83 has reached the high limit value." ::= { falconWellKnownAlarms 4031 } falconInput83LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 83 has reached the low limit value." ::= { falconWellKnownAlarms 4032 } falconInput83High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 83 has reached the high limit value." ::= { falconWellKnownAlarms 4033 } falconInput83Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 83 has reached the low limit value." ::= { falconWellKnownAlarms 4034 } falconInput84DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 84 has been activated." ::= { falconWellKnownAlarms 4040 } falconInput84HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 84 has reached the high limit value." ::= { falconWellKnownAlarms 4041 } falconInput84LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 84 has reached the low limit value." ::= { falconWellKnownAlarms 4042 } falconInput84High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 84 has reached the high limit value." ::= { falconWellKnownAlarms 4043 } falconInput84Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 84 has reached the low limit value." ::= { falconWellKnownAlarms 4044 } falconInput85DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 85 has been activated." ::= { falconWellKnownAlarms 4050 } falconInput85HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 85 has reached the high limit value." ::= { falconWellKnownAlarms 4051 } falconInput85LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 85 has reached the low limit value." ::= { falconWellKnownAlarms 4052 } falconInput85High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 85 has reached the high limit value." ::= { falconWellKnownAlarms 4053 } falconInput85Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 85 has reached the low limit value." ::= { falconWellKnownAlarms 4054 } falconInput86DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 86 has been activated." ::= { falconWellKnownAlarms 4060 } falconInput86HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 86 has reached the high limit value." ::= { falconWellKnownAlarms 4061 } falconInput86LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 86 has reached the low limit value." ::= { falconWellKnownAlarms 4062 } falconInput86High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 86 has reached the high limit value." ::= { falconWellKnownAlarms 4063 } falconInput86Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 86 has reached the low limit value." ::= { falconWellKnownAlarms 4064 } falconInput87DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 87 has been activated." ::= { falconWellKnownAlarms 4070 } falconInput87HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 87 has reached the high limit value." ::= { falconWellKnownAlarms 4071 } falconInput87LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 87 has reached the low limit value." ::= { falconWellKnownAlarms 4072 } falconInput87High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 87 has reached the high limit value." ::= { falconWellKnownAlarms 4073 } falconInput87Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 87 has reached the low limit value." ::= { falconWellKnownAlarms 4074 } falconInput88DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 88 has been activated." ::= { falconWellKnownAlarms 4080 } falconInput88HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 88 has reached the high limit value." ::= { falconWellKnownAlarms 4081 } falconInput88LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 88 has reached the low limit value." ::= { falconWellKnownAlarms 4082 } falconInput88High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 88 has reached the high limit value." ::= { falconWellKnownAlarms 4083 } falconInput88Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 88 has reached the low limit value." ::= { falconWellKnownAlarms 4084 } falconInput89DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 89 has been activated." ::= { falconWellKnownAlarms 4090 } falconInput89HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 89 has reached the high limit value." ::= { falconWellKnownAlarms 4091 } falconInput89LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 89 has reached the low limit value." ::= { falconWellKnownAlarms 4092 } falconInput89High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 89 has reached the high limit value." ::= { falconWellKnownAlarms 4093 } falconInput89Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 89 has reached the low limit value." ::= { falconWellKnownAlarms 4094 } falconInput90DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 90 has been activated." ::= { falconWellKnownAlarms 4100 } falconInput90HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 90 has reached the high limit value." ::= { falconWellKnownAlarms 4101 } falconInput90LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 90 has reached the low limit value." ::= { falconWellKnownAlarms 4102 } falconInput90High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 90 has reached the high limit value." ::= { falconWellKnownAlarms 4103 } falconInput90Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 90 has reached the low limit value." ::= { falconWellKnownAlarms 4104 } falconInput91DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 91 has been activated." ::= { falconWellKnownAlarms 4110 } falconInput91HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 91 has reached the high limit value." ::= { falconWellKnownAlarms 4111 } falconInput91LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 91 has reached the low limit value." ::= { falconWellKnownAlarms 4112 } falconInput91High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 91 has reached the high limit value." ::= { falconWellKnownAlarms 4113 } falconInput91Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 91 has reached the low limit value." ::= { falconWellKnownAlarms 4114 } falconInput92DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 92 has been activated." ::= { falconWellKnownAlarms 4120 } falconInput92HighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 92 has reached the high limit value." ::= { falconWellKnownAlarms 4121 } falconInput92LowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 92 has reached the low limit value." ::= { falconWellKnownAlarms 4122 } falconInput92High2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 92 has reached the high limit value." ::= { falconWellKnownAlarms 4123 } falconInput92Low2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for sensor 92 has reached the low limit value." ::= { falconWellKnownAlarms 4124 } falconInput93DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 93 has been activated." ::= { falconWellKnownAlarms 4130 } falconInput94DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 94 has been activated." ::= { falconWellKnownAlarms 4140 } falconInput95DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 95 has been activated." ::= { falconWellKnownAlarms 4150 } falconInput96DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 96 has been activated." ::= { falconWellKnownAlarms 4160 } falconInput97DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 97 has been activated." ::= { falconWellKnownAlarms 4170 } falconInput98DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 98 has been activated." ::= { falconWellKnownAlarms 4180 } falconInput99DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 99 has been activated." ::= { falconWellKnownAlarms 4190 } falconInput100DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 100 has been activated." ::= { falconWellKnownAlarms 4200 } falconInput101DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 101 has been activated." ::= { falconWellKnownAlarms 4210 } falconInput102DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 102 has been activated." ::= { falconWellKnownAlarms 4220 } falconInput103DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 103 has been activated." ::= { falconWellKnownAlarms 4230 } falconInput104DigAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The digital input 104 has been activated." ::= { falconWellKnownAlarms 4240 } falconTemperatureSensorHighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal temperature sensor has reached the high limit value." ::= { falconWellKnownAlarms 5011 } falconTemperatureSensorLowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal temperature sensor has reached the low limit value." ::= { falconWellKnownAlarms 5012 } falconTemperatureSensorHigh2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal temperature sensor has reached the high limit value." ::= { falconWellKnownAlarms 5013 } falconTemperatureSensorLow2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal temperature sensor has reached the low limit value." ::= { falconWellKnownAlarms 5014 } falconHumiditySensorHighAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal humidity sensor has reached the high limit value." ::= { falconWellKnownAlarms 5021 } falconHumiditySensorLowAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal humidity sensor has reached the low limit value." ::= { falconWellKnownAlarms 5022 } falconHumiditySensorHigh2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal humidity sensor has reached the high limit value." ::= { falconWellKnownAlarms 5023 } falconHumiditySensorLow2Alarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The reading for internal humidity sensor has reached the low limit value." ::= { falconWellKnownAlarms 5024 } falconLowBatteryAlarm OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "The Faclon has detected a low battery condition." ::= { falconWellKnownAlarms 6010 } falconTraps OBJECT IDENTIFIER ::= { falcon-emMIB 6 } falconAlarmEntryAdded TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An AlarmEntryAdded Trap signifies that the a sensor reading has reached a high or low limit value." ::= 1 falconAlarmEntryRemoved TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An AlarmEntryAdded Trap signifies that the a sensor reading has gone below the high limit value or above the low limit value." ::= 2 falconAccessGranted TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An falconAccessGranted Trap signifies that a valid key code sequence was processed by the falcon." ::= 3 falconAccessDenied TRAP-TYPE ENTERPRISE falconTraps DESCRIPTION "An falconAccessedDenied Trap signifies that an invalid key code sequence was processed by the falcon." ::= 4 falconPageUnsuccessful TRAP-TYPE ENTERPRISE falconTraps VARIABLES { falconPagerStatusString } DESCRIPTION "An falconPageUnsuccessful Trap signifies that an alpha numeric page could not be sent to the service." ::= 5 falconConfigurationChanged TRAP-TYPE ENTERPRISE falconTraps VARIABLES { falconWebUser } DESCRIPTION "A falconConfigurationChanged Trap is sent upon configuration changhes made to the falcon via a web page." ::= 6 falconAlarmHistory OBJECT IDENTIFIER ::= { falcon-emMIB 7 } falconAlarmHistoryEntries OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The present number of entries in the alarm history." ::= { falconAlarmHistory 1 } falconAlarmHistoryClear OBJECT-TYPE SYNTAX INTEGER { clearBuffer(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to ClearBuffer(1) will clear the alarm history buffer. " ::= { falconAlarmHistory 2 } falconAlarmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of alarm history table entries stored in the in the non-volatile memory. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The falcon creates a row in the table each time a new alarm is detected. The falcon creates the first row with falconAlarmHistoryId equal to 1, and increments the value of falconAlarmHistoryId each time a new row is created, up to a maximum of 100. After 100 entries are created, the falcon will overwrite the earliest entry with the latest alarm. The number of rows in the table at any given time is reflected by the value of falconAlarmHistoryEntries." ::= { falconAlarmHistory 3 } falconAlarmHistoryEntry OBJECT-TYPE SYNTAX FalconAlarmHistoryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing information applicable to a particular alarm history entry." INDEX { falconAlarmHistoryId } ::= { falconAlarmHistoryTable 1 } FalconAlarmHistoryEntry ::= SEQUENCE { falconAlarmHistoryId PositiveInteger, falconAlarmHistoryText DisplayString } falconAlarmHistoryId OBJECT-TYPE SYNTAX PositiveInteger ACCESS not-accessible STATUS mandatory DESCRIPTION "A unique identifier for an alarm condition. This value must remain constant." ::= { falconAlarmHistoryEntry 1 } falconAlarmHistoryText OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A text desciption of the alarm history entry. Each of the strings will have the following format, AHxxx-id-type-timestamp label xxx = number entry in the table id = Alarm ID type = HIGH, LOW, ALM or RTN timestamp = MM/DD/YY HH:MM:SS Label = The label associated with the input channel" ::= { falconAlarmHistoryEntry 2 } falconTrapSettings OBJECT IDENTIFIER ::= { falcon-emMIB 8 } falconPersistantTraps OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "The number of minutes between persistant traps. Set this to 0 to turn off persistant traps." ::= { falconTrapSettings 1 } falconAlarmAcknowledge OBJECT-TYPE SYNTAX INTEGER { acknowledgeAlarms(1) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to AcknowledgeAlarms(1) will stop the falcon from sending persistant traps and dial out sequences." ::= { falconTrapSettings 2 } falconSchedules OBJECT IDENTIFIER ::= { falcon-emMIB 9 } falconScheduleABeginDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The beginning day of the week for schedule A." ::= { falconSchedules 1 } falconScheduleAEndDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The ending day of the week for schedule A." ::= { falconSchedules 2 } falconScheduleABeginTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule A beginning time of day. Displayed as HH:MM" ::= { falconSchedules 3 } falconScheduleAEndTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule A ending time of day. Displayed as HH:MM" ::= { falconSchedules 4 } falconScheduleBBeginDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The beginning day of the week for schedule B." ::= { falconSchedules 5 } falconScheduleBEndDOW OBJECT-TYPE SYNTAX INTEGER { sunday(1), monday(2), tuesday(3), wednesday(4), thursday(5), friday(6), saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The ending day of the week for schedule B." ::= { falconSchedules 6 } falconScheduleBBeginTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule B beginning time of day. Displayed as HH:MM" ::= { falconSchedules 7 } falconScheduleBEndTime OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The schedule B ending time of day. Displayed as HH:MM" ::= { falconSchedules 8 } falconPortTrap OBJECT IDENTIFIER ::= { falcon-emMIB 10 } falconPort01Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #01 has reached an alarm state." ::= 1 falconPort02Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #02 has reached an alarm state." ::= 2 falconPort03Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #03 has reached an alarm state." ::= 3 falconPort04Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #04 has reached an alarm state." ::= 4 falconPort05Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #05 has reached an alarm state." ::= 5 falconPort06Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #06 has reached an alarm state." ::= 6 falconPort07Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #07 has reached an alarm state." ::= 7 falconPort08Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #08 has reached an alarm state." ::= 8 falconPort09Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #09 has reached an alarm state." ::= 9 falconPort10Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #10 has reached an alarm state." ::= 10 falconPort11Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #11 has reached an alarm state." ::= 11 falconPort12Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #12 has reached an alarm state." ::= 12 falconPort13Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #13 has reached an alarm state." ::= 13 falconPort14Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #14 has reached an alarm state." ::= 14 falconPort15Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #15 has reached an alarm state." ::= 15 falconPort16Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #16 has reached an alarm state." ::= 16 falconPort17Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #17 has reached an alarm state." ::= 17 falconPort18Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #18 has reached an alarm state." ::= 18 falconPort19Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #19 has reached an alarm state." ::= 19 falconPort20Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #20 has reached an alarm state." ::= 20 falconPort21Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #21 has reached an alarm state." ::= 21 falconPort22Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #22 has reached an alarm state." ::= 22 falconPort23Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #23 has reached an alarm state." ::= 23 falconPort24Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #24 has reached an alarm state." ::= 24 falconPort25Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #25 has reached an alarm state." ::= 25 falconPort26Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #26 has reached an alarm state." ::= 26 falconPort27Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #27 has reached an alarm state." ::= 27 falconPort28Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #28 has reached an alarm state." ::= 28 falconPort29Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #29 has reached an alarm state." ::= 29 falconPort30Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #30 has reached an alarm state." ::= 30 falconPort31Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #31 has reached an alarm state." ::= 31 falconPort32Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #32 has reached an alarm state." ::= 32 falconPort33Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #33 has reached an alarm state." ::= 33 falconPort34Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #34 has reached an alarm state." ::= 34 falconPort35Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #35 has reached an alarm state." ::= 35 falconPort36Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #36 has reached an alarm state." ::= 36 falconPort37Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #37 has reached an alarm state." ::= 37 falconPort38Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #38 has reached an alarm state." ::= 38 falconPort39Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #39 has reached an alarm state." ::= 39 falconPort40Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #40 has reached an alarm state." ::= 40 falconPort41Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #41 has reached an alarm state." ::= 41 falconPort42Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #42 has reached an alarm state." ::= 42 falconPort43Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #43 has reached an alarm state." ::= 43 falconPort44Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #44 has reached an alarm state." ::= 44 falconPort45Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #45 has reached an alarm state." ::= 45 falconPort46Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #46 has reached an alarm state." ::= 46 falconPort47Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #47 has reached an alarm state." ::= 47 falconPort48Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #48 has reached an alarm state." ::= 48 falconPort49Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #49 has reached an alarm state." ::= 49 falconPort50Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #50 has reached an alarm state." ::= 50 falconPort51Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #51 has reached an alarm state." ::= 51 falconPort52Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #52 has reached an alarm state." ::= 52 falconPort53Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #53 has reached an alarm state." ::= 53 falconPort54Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #54 has reached an alarm state." ::= 54 falconPort55Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #55 has reached an alarm state." ::= 55 falconPort56Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #56 has reached an alarm state." ::= 56 falconPort57Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #57 has reached an alarm state." ::= 57 falconPort58Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #58 has reached an alarm state." ::= 58 falconPort59Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #59 has reached an alarm state." ::= 59 falconPort60Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #60 has reached an alarm state." ::= 60 falconPort61Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #61 has reached an alarm state." ::= 61 falconPort62Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #62 has reached an alarm state." ::= 62 falconPort63Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #63 has reached an alarm state." ::= 63 falconPort64Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #64 has reached an alarm state." ::= 64 falconPort65Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #65 has reached an alarm state." ::= 65 falconPort66Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #66 has reached an alarm state." ::= 66 falconPort67Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #67 has reached an alarm state." ::= 67 falconPort68Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #68 has reached an alarm state." ::= 68 falconPort69Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #69 has reached an alarm state." ::= 69 falconPort70Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #70 has reached an alarm state." ::= 70 falconPort71Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #71 has reached an alarm state." ::= 71 falconPort72Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #72 has reached an alarm state." ::= 72 falconPort73Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #73 has reached an alarm state." ::= 73 falconPort74Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #74 has reached an alarm state." ::= 74 falconPort75Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #75 has reached an alarm state." ::= 75 falconPort76Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #76 has reached an alarm state." ::= 76 falconPort77Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #77 has reached an alarm state." ::= 77 falconPort78Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #78 has reached an alarm state." ::= 78 falconPort79Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #79 has reached an alarm state." ::= 79 falconPort80Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #80 has reached an alarm state." ::= 80 falconPort81Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #81 has reached an alarm state." ::= 81 falconPort82Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #82 has reached an alarm state." ::= 82 falconPort83Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #83 has reached an alarm state." ::= 83 falconPort84Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #84 has reached an alarm state." ::= 84 falconPort85Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #85 has reached an alarm state." ::= 85 falconPort86Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #86 has reached an alarm state." ::= 86 falconPort87Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #87 has reached an alarm state." ::= 87 falconPort88Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #88 has reached an alarm state." ::= 88 falconPort89Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #89 has reached an alarm state." ::= 89 falconPort90Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #90 has reached an alarm state." ::= 90 falconPort91Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #91 has reached an alarm state." ::= 91 falconPort92Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #92 has reached an alarm state." ::= 92 falconPort93Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #93 has reached an alarm state." ::= 93 falconPort94Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #94 has reached an alarm state." ::= 94 falconPort95Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #95 has reached an alarm state." ::= 95 falconPort96Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #96 has reached an alarm state." ::= 96 falconPort97Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #97 has reached an alarm state." ::= 97 falconPort98Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #98 has reached an alarm state." ::= 98 falconPort99Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #99 has reached an alarm state." ::= 99 falconPort100Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #100 has reached an alarm state." ::= 100 falconPort101Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #101 has reached an alarm state." ::= 101 falconPort102Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #102 has reached an alarm state." ::= 102 falconPort103Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #103 has reached an alarm state." ::= 103 falconPort104Trap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #104 has reached an alarm state." ::= 104 falconTemperatureSensorTrap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconTemperatureSensorLabel, falconTemperatureSensorReading, falconTemperatureSensorUOM } DESCRIPTION "The internal temperature sensor has reached an alarm state." ::= 105 falconHumiditySensorTrap TRAP-TYPE ENTERPRISE falconPortTrap VARIABLES { falconAlarmId, falconAlarmDescr, falconHumiditySensorLabel, falconHumiditySensorReading, falconHumiditySensorUOM } DESCRIPTION "The internal Humidity sensor has reached an alarm state." ::= 106 falconPortTrapClear OBJECT IDENTIFIER ::= { falcon-emMIB 11 } falconPort01TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #01 has returned to normal." ::= 1 falconPort02TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #02 has returned to normal." ::= 2 falconPort03TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #03 has returned to normal." ::= 3 falconPort04TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #04 has returned to normal." ::= 4 falconPort05TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #05 has returned to normal." ::= 5 falconPort06TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #06 has returned to normal." ::= 6 falconPort07TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #07 has returned to normal." ::= 7 falconPort08TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #08 has returned to normal." ::= 8 falconPort09TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #09 has returned to normal." ::= 9 falconPort10TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #10 has returned to normal." ::= 10 falconPort11TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #11 has returned to normal." ::= 11 falconPort12TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #12 has returned to normal." ::= 12 falconPort13TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #13 has returned to normal." ::= 13 falconPort14TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #14 has returned to normal." ::= 14 falconPort15TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #15 has returned to normal." ::= 15 falconPort16TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #16 has returned to normal." ::= 16 falconPort17TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #17 has returned to normal." ::= 17 falconPort18TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #18 has returned to normal." ::= 18 falconPort19TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #19 has returned to normal." ::= 19 falconPort20TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #20 has returned to normal." ::= 20 falconPort21TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #21 has returned to normal." ::= 21 falconPort22TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #22 has returned to normal." ::= 22 falconPort23TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #23 has returned to normal." ::= 23 falconPort24TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #24 has returned to normal." ::= 24 falconPort25TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #25 has returned to normal." ::= 25 falconPort26TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #26 has returned to normal." ::= 26 falconPort27TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #27 has returned to normal." ::= 27 falconPort28TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #28 has returned to normal." ::= 28 falconPort29TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #29 has returned to normal." ::= 29 falconPort30TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #30 has returned to normal." ::= 30 falconPort31TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #31 has returned to normal." ::= 31 falconPort32TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #32 has returned to normal." ::= 32 falconPort33TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #33 has returned to normal." ::= 33 falconPort34TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #34 has returned to normal." ::= 34 falconPort35TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #35 has returned to normal." ::= 35 falconPort36TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #36 has returned to normal." ::= 36 falconPort37TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #37 has returned to normal." ::= 37 falconPort38TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #38 has returned to normal." ::= 38 falconPort39TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #39 has returned to normal." ::= 39 falconPort40TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #40 has returned to normal." ::= 40 falconPort41TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #41 has returned to normal." ::= 41 falconPort42TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #42 has returned to normal." ::= 42 falconPort43TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #43 has returned to normal." ::= 43 falconPort44TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #44 has returned to normal." ::= 44 falconPort45TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #45 has returned to normal." ::= 45 falconPort46TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #46 has returned to normal." ::= 46 falconPort47TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #47 has returned to normal." ::= 47 falconPort48TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #48 has returned to normal." ::= 48 falconPort49TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #49 has returned to normal." ::= 49 falconPort50TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #50 has returned to normal." ::= 50 falconPort51TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #51 has returned to normal." ::= 51 falconPort52TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #52 has returned to normal." ::= 52 falconPort53TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #53 has returned to normal." ::= 53 falconPort54TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #54 has returned to normal." ::= 54 falconPort55TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #55 has returned to normal." ::= 55 falconPort56TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #56 has returned to normal." ::= 56 falconPort57TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #57 has returned to normal." ::= 57 falconPort58TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #58 has returned to normal." ::= 58 falconPort59TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #59 has returned to normal." ::= 59 falconPort60TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #60 has returned to normal." ::= 60 falconPort61TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #61 has returned to normal." ::= 61 falconPort62TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #62 has returned to normal." ::= 62 falconPort63TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #63 has returned to normal." ::= 63 falconPort64TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #64 has returned to normal." ::= 64 falconPort65TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #65 has returned to normal." ::= 65 falconPort66TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #66 has returned to normal." ::= 66 falconPort67TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #67 has returned to normal." ::= 67 falconPort68TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #68 has returned to normal." ::= 68 falconPort69TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #69 has returned to normal." ::= 69 falconPort70TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #70 has returned to normal." ::= 70 falconPort71TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #71 has returned to normal." ::= 71 falconPort72TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #72 has returned to normal." ::= 72 falconPort73TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #73 has returned to normal." ::= 73 falconPort74TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #74 has returned to normal." ::= 74 falconPort75TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #75 has returned to normal." ::= 75 falconPort76TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #76 has returned to normal." ::= 76 falconPort77TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #77 has returned to normal." ::= 77 falconPort78TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #78 has returned to normal." ::= 78 falconPort79TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #79 has returned to normal." ::= 79 falconPort80TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #80 has returned to normal." ::= 80 falconPort81TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #81 has returned to normal." ::= 81 falconPort82TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #82 has returned to normal." ::= 82 falconPort83TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #83 has returned to normal." ::= 83 falconPort84TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #84 has returned to normal." ::= 84 falconPort85TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #85 has returned to normal." ::= 85 falconPort86TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #86 has returned to normal." ::= 86 falconPort87TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #87 has returned to normal." ::= 87 falconPort88TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #88 has returned to normal." ::= 88 falconPort89TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #89 has returned to normal." ::= 89 falconPort90TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #90 has returned to normal." ::= 90 falconPort91TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #91 has returned to normal." ::= 91 falconPort92TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #92 has returned to normal." ::= 92 falconPort93TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #93 has returned to normal." ::= 93 falconPort94TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #94 has returned to normal." ::= 94 falconPort95TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #95 has returned to normal." ::= 95 falconPort96TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #96 has returned to normal." ::= 96 falconPort97TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #97 has returned to normal." ::= 97 falconPort98TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #98 has returned to normal." ::= 98 falconPort99TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #99 has returned to normal." ::= 99 falconPort100TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #100 has returned to normal." ::= 100 falconPort101TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #101 has returned to normal." ::= 101 falconPort102TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #102 has returned to normal." ::= 102 falconPort103TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #103 has returned to normal." ::= 103 falconPort104TrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconInputLabel, falconInputReading, falconInputUOM } DESCRIPTION "The sensor on port #104 has returned to normal." ::= 104 falconTemperatureSensorTrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconTemperatureSensorLabel, falconTemperatureSensorReading, falconTemperatureSensorUOM } DESCRIPTION "The internal temperature sensor has returned to normal." ::= 105 falconHumiditySensorTrapClear TRAP-TYPE ENTERPRISE falconPortTrapClear VARIABLES { falconAlarmId, falconAlarmDescr, falconHumiditySensorLabel, falconHumiditySensorReading, falconHumiditySensorUOM } DESCRIPTION "The internal Humidity sensor has returned to normal." ::= 106 falconXbus OBJECT IDENTIFIER ::= { falcon-emMIB 12 } falconBCMs OBJECT IDENTIFIER ::= { falconXbus 1 } falconBCM01 OBJECT IDENTIFIER ::= { falconBCMs 1 } falconBCM01Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the BCM." ::= { falconBCM01 1 } falconBCM01CBTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconBCM01CBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon modbus BCM CB port status." ::= { falconBCM01 2 } falconBCM01CBEntry OBJECT-TYPE SYNTAX FalconBCM01Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon modbus BCM CB port." INDEX { falconBCM01CBIndex } ::= { falconBCM01CBTable 1 } FalconBCM01CBEntry ::= SEQUENCE { falconBCM01CBIndex INTEGER, falconBCM01CBStatus INTEGER, falconBCM01CBReading INTEGER, falconBCM01CBLabel DisplayString } falconBCM01CBIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each BCM CB port. Its value ranges between 1 and 42." ::= { falconBCM01CBEntry 1 } falconBCM01CBStatus OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), offline(1), normal(2), zeroAmpAlarm(3), warning(4), alarm(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this circuit breaker." ::= { falconBCM01CBEntry 2 } falconBCM01CBReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The current reading (AMPS) for circuit breaker." ::= { falconBCM01CBEntry 3 } falconBCM01CBLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the circuit breaker." ::= { falconBCM01CBEntry 4 } falconBCM02 OBJECT IDENTIFIER ::= { falconBCMs 2 } falconBCM02Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the BCM." ::= { falconBCM02 1 } falconBCM02CBTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconBCM02CBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon modbus BCM CB port status." ::= { falconBCM02 2 } falconBCM02CBEntry OBJECT-TYPE SYNTAX FalconBCM02Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon modbus BCM CB port." INDEX { falconBCM02CBIndex } ::= { falconBCM02CBTable 1 } FalconBCM02CBEntry ::= SEQUENCE { falconBCM02CBIndex INTEGER, falconBCM02CBStatus INTEGER, falconBCM02CBReading INTEGER, falconBCM02CBLabel DisplayString } falconBCM02CBIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each BCM CB port. Its value ranges between 1 and 42." ::= { falconBCM02CBEntry 1 } falconBCM02CBStatus OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), offline(1), normal(2), zeroAmpAlarm(3), warning(4), alarm(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this circuit breaker." ::= { falconBCM02CBEntry 2 } falconBCM02CBReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The current reading (AMPS) for circuit breaker." ::= { falconBCM02CBEntry 3 } falconBCM02CBLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the circuit breaker." ::= { falconBCM02CBEntry 4 } falconBCM03 OBJECT IDENTIFIER ::= { falconBCMs 3 } falconBCM03Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the BCM." ::= { falconBCM03 1 } falconBCM03CBTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconBCM03CBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon modbus BCM CB port status." ::= { falconBCM03 2 } falconBCM03CBEntry OBJECT-TYPE SYNTAX FalconBCM03Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon modbus BCM CB port." INDEX { falconBCM03CBIndex } ::= { falconBCM03CBTable 1 } FalconBCM03CBEntry ::= SEQUENCE { falconBCM03CBIndex INTEGER, falconBCM03CBStatus INTEGER, falconBCM03CBReading INTEGER, falconBCM03CBLabel DisplayString } falconBCM03CBIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each BCM CB port. Its value ranges between 1 and 42." ::= { falconBCM03CBEntry 1 } falconBCM03CBStatus OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), offline(1), normal(2), zeroAmpAlarm(3), warning(4), alarm(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this circuit breaker." ::= { falconBCM03CBEntry 2 } falconBCM03CBReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The current reading (AMPS) for circuit breaker." ::= { falconBCM03CBEntry 3 } falconBCM03CBLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the circuit breaker." ::= { falconBCM03CBEntry 4 } falconBCM04 OBJECT IDENTIFIER ::= { falconBCMs 4 } falconBCM04Label OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the BCM." ::= { falconBCM04 1 } falconBCM04CBTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconBCM04CBEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon modbus BCM CB port status." ::= { falconBCM04 2 } falconBCM04CBEntry OBJECT-TYPE SYNTAX FalconBCM04Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon modbus BCM CB port." INDEX { falconBCM04CBIndex } ::= { falconBCM04CBTable 1 } FalconBCM04CBEntry ::= SEQUENCE { falconBCM04CBIndex INTEGER, falconBCM04CBStatus INTEGER, falconBCM04CBReading INTEGER, falconBCM04CBLabel DisplayString } falconBCM04CBIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each BCM CB port. Its value ranges between 1 and 42." ::= { falconBCM04CBEntry 1 } falconBCM04CBStatus OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), offline(1), normal(2), zeroAmpAlarm(3), warning(4), alarm(5) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this circuit breaker." ::= { falconBCM04CBEntry 2 } falconBCM04CBReading OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The current reading (AMPS) for circuit breaker." ::= { falconBCM04CBEntry 3 } falconBCM04CBLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the circuit breaker." ::= { falconBCM04CBEntry 4 } falconBCMTrap OBJECT IDENTIFIER ::= { falconXbus 2 } falconBCM01Trap TRAP-TYPE ENTERPRISE falconBCMTrap VARIABLES { falconAlarmId, falconBCM01CBIndex, falconBCM01CBStatus, falconBCM01CBLabel, falconBCM01CBReading } DESCRIPTION "The current on a BCM #01 circuit breaker has reached an alarm state." ::= 1 falconBCM02Trap TRAP-TYPE ENTERPRISE falconBCMTrap VARIABLES { falconAlarmId, falconBCM02CBIndex, falconBCM02CBStatus, falconBCM02CBLabel, falconBCM02CBReading } DESCRIPTION "The current on a BCM #02 circuit breaker has reached an alarm state." ::= 2 falconBCM03Trap TRAP-TYPE ENTERPRISE falconBCMTrap VARIABLES { falconAlarmId, falconBCM03CBIndex, falconBCM03CBStatus, falconBCM03CBLabel, falconBCM03CBReading } DESCRIPTION "The current on a BCM #03 circuit breaker has reached an alarm state." ::= 3 falconBCM04Trap TRAP-TYPE ENTERPRISE falconBCMTrap VARIABLES { falconAlarmId, falconBCM04CBIndex, falconBCM04CBStatus, falconBCM04CBLabel, falconBCM04CBReading } DESCRIPTION "The current on a BCM #04 circuit breaker has reached an alarm state." ::= 4 falconBCMTrapClear OBJECT IDENTIFIER ::= { falconXbus 3 } falconBCM01TrapClear TRAP-TYPE ENTERPRISE falconBCMTrapClear VARIABLES { falconAlarmId, falconBCM01CBIndex, falconBCM01CBStatus, falconBCM01CBLabel, falconBCM01CBReading } DESCRIPTION "The current on a BCM #01 circuit breaker has returned to normal." ::= 1 falconBCM02TrapClear TRAP-TYPE ENTERPRISE falconBCMTrapClear VARIABLES { falconAlarmId, falconBCM02CBIndex, falconBCM02CBStatus, falconBCM02CBLabel, falconBCM02CBReading } DESCRIPTION "The current on a BCM #02 circuit breaker has returned to normal." ::= 2 falconBCM03TrapClear TRAP-TYPE ENTERPRISE falconBCMTrapClear VARIABLES { falconAlarmId, falconBCM03CBIndex, falconBCM03CBStatus, falconBCM03CBLabel, falconBCM03CBReading } DESCRIPTION "The current on a BCM #03 circuit breaker has returned to normal." ::= 3 falconBCM04TrapClear TRAP-TYPE ENTERPRISE falconBCMTrapClear VARIABLES { falconAlarmId, falconBCM04CBIndex, falconBCM04CBStatus, falconBCM04CBLabel, falconBCM04CBReading } DESCRIPTION "The current on a BCM #04 circuit breaker has returned to normal." ::= 4 falconXbG628 OBJECT IDENTIFIER ::= { falconXbus 4 } falconXbUnits OBJECT IDENTIFIER ::= { falconXbG628 1 } falconXbUnitsTable OBJECT-TYPE SYNTAX SEQUENCE OF FalconXbUnitsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of the falcon modbus/bacnet unit status." ::= { falconXbUnits 1 } falconXbUnitsEntry OBJECT-TYPE SYNTAX FalconXbUnitsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry containing objects for the Falcon modbus/bacnet unit status." INDEX { falconXbUnitsIndex } ::= { falconXbUnitsTable 1 } FalconXbUnitsEntry ::= SEQUENCE { falconXbUnitsIndex INTEGER, falconXbUnitsStatus INTEGER, falconXbUnitsLabel DisplayString } falconXbUnitsIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each Modbus/bacnet unit. Its value ranges between 1 and 16." ::= { falconXbUnitsEntry 1 } falconXbUnitsStatus OBJECT-TYPE SYNTAX INTEGER { notConfigured(0), offline(1), normal(2), alarm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current status for this Modbus/bacnet unit." ::= { falconXbUnitsEntry 2 } falconXbUnitsLabel OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined text string associated with the Modbus/bacnet unit." ::= { falconXbUnitsEntry 3 } falconXbusTrapData OBJECT IDENTIFIER ::= { falconXbG628 2 } falconXbusTrapRegisterNumber OBJECT-TYPE SYNTAX PositiveInteger ACCESS not-accessible STATUS mandatory DESCRIPTION "A Modbus register number (e.g. 40001) or bacnet instance number (e.g. 770033)." ::= { falconXbusTrapData 1 } falconXbusTrapRegisterLabel OBJECT-TYPE SYNTAX DisplayString ACCESS not-accessible STATUS mandatory DESCRIPTION "A user-defined text string associated with the Modbus register or bacnet instance" ::= { falconXbusTrapData 2 } falconXbusTraps OBJECT IDENTIFIER ::= { falconXbus 5 } falconXbusTrap TRAP-TYPE ENTERPRISE falconXbusTraps VARIABLES { falconAlarmId, falconXbUnitsIndex, falconXbUnitsStatus, falconXbUnitsLabel, falconXbusTrapRegisterNumber, falconXbusTrapRegisterLabel } DESCRIPTION "A Modbus/bacnet device has reached an alarm state." ::= 1 falconXbusTrapsClear OBJECT IDENTIFIER ::= { falconXbus 6 } falconXbusTrapClear TRAP-TYPE ENTERPRISE falconXbusTrapsClear VARIABLES { falconAlarmId, falconXbUnitsIndex, falconXbUnitsStatus, falconXbUnitsLabel, falconXbusTrapRegisterNumber, falconXbusTrapRegisterLabel } DESCRIPTION "A Modbus/bacnet device has returned to normal." ::= 1 -- -- The falcon Extension -- fms-X OBJECT IDENTIFIER ::= { falcon-em 2 } fms-A OBJECT IDENTIFIER ::= { falcon-em 3 } fms-B OBJECT IDENTIFIER ::= { falcon-em 4 } fms-C OBJECT IDENTIFIER ::= { falcon-em 5 } fms-AAxx OBJECT IDENTIFIER ::= { falcon-em 3300 } fms-AAAx OBJECT IDENTIFIER ::= { falcon-em 3330 } fms-AAAA OBJECT IDENTIFIER ::= { falcon-em 3333 } fms-AAAC OBJECT IDENTIFIER ::= { falcon-em 3335 } fms-AABx OBJECT IDENTIFIER ::= { falcon-em 3340 } fms-AABB OBJECT IDENTIFIER ::= { falcon-em 3344 } fms-AACx OBJECT IDENTIFIER ::= { falcon-em 3350 } fms-AACC OBJECT IDENTIFIER ::= { falcon-em 3355 } fms-ABxx OBJECT IDENTIFIER ::= { falcon-em 3400 } fms-ABBx OBJECT IDENTIFIER ::= { falcon-em 3440 } fms-ABBB OBJECT IDENTIFIER ::= { falcon-em 3444 } fms-ABBC OBJECT IDENTIFIER ::= { falcon-em 3445 } fms-ABCx OBJECT IDENTIFIER ::= { falcon-em 3450 } fms-ABCC OBJECT IDENTIFIER ::= { falcon-em 3455 } fms-ACxx OBJECT IDENTIFIER ::= { falcon-em 3500 } fms-ACCx OBJECT IDENTIFIER ::= { falcon-em 3550 } fms-ACCC OBJECT IDENTIFIER ::= { falcon-em 3555 } fms-BBxx OBJECT IDENTIFIER ::= { falcon-em 4400 } fms-BBBx OBJECT IDENTIFIER ::= { falcon-em 4440 } fms-BBBB OBJECT IDENTIFIER ::= { falcon-em 4444 } fms-BBBC OBJECT IDENTIFIER ::= { falcon-em 4445 } fms-BBCx OBJECT IDENTIFIER ::= { falcon-em 4450 } fms-BBCC OBJECT IDENTIFIER ::= { falcon-em 4455 } fms-BCxx OBJECT IDENTIFIER ::= { falcon-em 4500 } fms-BCCx OBJECT IDENTIFIER ::= { falcon-em 4550 } fms-BCCC OBJECT IDENTIFIER ::= { falcon-em 4555 } fms-CCxx OBJECT IDENTIFIER ::= { falcon-em 5500 } fms-CxCC OBJECT IDENTIFIER ::= { falcon-em 5055 } fms-CCxC OBJECT IDENTIFIER ::= { falcon-em 5505 } fms-CCCx OBJECT IDENTIFIER ::= { falcon-em 5550 } fms-CCCC OBJECT IDENTIFIER ::= { falcon-em 5555 } END