Data centers frequently use the space under their raised floors to deliver cooling throughout their facilities.  Air is pushed into these underfloor spaces by perimeter computer room air conditioners (CRACs) or from high volume air handlers. Unfortunately, many raised floor data centers have shallow plenums and/or clutter under the floor. The result? High velocity horizontal underfloor air: the large amount of forced air is pressed into a small, restricted underfloor space and travels through so quickly that standard perforated floor panels simply cannot keep up.

How does a facility manager harness this high velocity airflow? Drop RLE’s slotted and chamfer high CFM airflow panels into your existing raised floor. These panels feature patented hi-plume stratification fins that grab air and redirect it up, out of the plenum space and into the room, delivering the air to the rack inlets.  In fact, Triad’s high CFM airflow panels have been proven – through independent laboratory testing and validation – to be superior to all other perforated panels in the market when used in data center applications with high underfloor velocities.

One of our customers learned firsthand how important airflow is to a cooling system. He kept close tabs on facility metrics and evaluated power usage and high fan speeds, quickly learning that he needed to reduce and eliminate supply air recirculation and return air net bypass air.

Our customer knew based on the amount of floor space and quantity of CRAC units in his facility that he was exceeding his CRAC cooling capacity. He just needed to be able to deliver the air to the right locations in the racks and was referred to RLE. He was immediately impressed by the quality of our floor panel construction, the patented drop-away handles, and the ingenuity behind our stratification fins and high CFM design.

We all know seeing is believing, so we gave him a slotted panel to try out in his facility. He dropped it into his existing flooring structure and watched as the highest rack temperature in the room dropped 15 degrees in front of the rack and 10 degrees in the back. Our customer had found his solution. He was sold, and implemented the panels strategically throughout his facility.

He still sees the benefits of Triad panels and their efficiency was underscored when he noticed his temperatures were way off in one cold aisle. He walked the floor and realized someone had lifted four panels and had placed them in the wrong direction – the panels had been rotated so the stratification fins were not directing the flow of air correctly. He popped the four tiles up and reoriented their position into the floor. The fix was quick, easy, and he saw immediate correction of temperature in his data center.

While it may seem that all floor panels are created the same, we know empirically that is far from the truth. Nearly all raised floor data centers have deployed standard 25% or 56% perforated panels. There is significant opportunity to replace these panels with Triad slotted or chamfer panels and save both capital and operating expenses.